MR measurement and numerical simulation of steady flow in an end-to-side anastomosis model

被引:20
作者
Steinman, DA
Frayne, R
Zhang, XD
Rutt, BK
Ethier, CR
机构
[1] UNIV TORONTO,DEPT MECH ENGN,TORONTO,ON M5S 1A4,CANADA
[2] UNIV WESTERN ONTARIO,DEPT DIAGNOST RADIOL,LONDON,ON,CANADA
[3] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON,ON,CANADA
[4] JOHN P ROBARTS RES INST,TOM LAWSON FAMILY IMAGING RES LABS,LONDON,ON N6A 5K8,CANADA
关键词
MR imaging; phase contrast; numerical simulation; hemodynamics; end-to-side anastomosis;
D O I
10.1016/0021-9290(95)00080-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic resonance phase contrast velocity imaging ('MR PC velocimetry') is a powerful tool for measuring blood velocity. While it has been demonstrated that MR PC velocimetry can accurately measure velocity profiles in simple, unidirectional flows, errors can arise when measuring the more complex, multidirectional flows of clinical importance. In this work, we have compared MR PC velocity measurements with numerical simulations of steady Bow in a physiologically relevant model of an end-to-side anastomosis, which produces many of the complex Bow features expected in vivo. MR PC velocity profiles, measured using both 2D and 3D pulse sequences, showed very good agreement with numerically computed profiles, although at 2D PC data showed slightly larger errors than the 3D PC data in regions of high accelerations and oblique Row, likely due to displacement artifacts. We conclude that, under ideal conditions, MR phase contrast velocimetry can measure complex flow patterns to within 15% accuracy, but that care should be taken when using 2D pulse sequences to measure such complex flows.
引用
收藏
页码:537 / 542
页数:6
相关论文
共 16 条
[1]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[2]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[3]  
FRAYNE R, IN PRESS J MAG RESON
[4]  
FRAYNE R, 1991, P SMRM 1991, P365
[5]   EVALUATION OF MAGNETIC-RESONANCE VELOCIMETRY FOR STEADY FLOW [J].
KU, DN ;
BIANCHERI, CL ;
PETTIGREW, RI ;
PEIFER, JW ;
MARKOU, CP ;
ENGELS, H .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (04) :464-472
[6]  
Nichols W.W., 1990, MCDONALDS BLOOD FLOW
[7]   ON THE NATURE AND REDUCTION OF THE DISPLACEMENT ARTIFACT IN FLOW IMAGES [J].
NISHIMURA, DG ;
JACKSON, JI ;
PAULY, JM .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) :481-492
[8]  
OJHA M, 1990, J VASC SURG, V20, P311
[9]  
PEDERSEN EM, 1993, P SMRM, P670
[10]  
SMITH RF, 1994, P SOC PHOTO-OPT INS, V2163, P235, DOI 10.1117/12.174260