Four-color multiplex reverse transcription polymerase chain reaction - Overcoming its limitations

被引:44
作者
Persson, K [1 ]
Hamby, K [1 ]
Ugozzoli, LA [1 ]
机构
[1] BioRad Labs, Gene Express Div, Hercules, CA 94547 USA
关键词
real-time PCR; RT-PCR; PCR; gene expression;
D O I
10.1016/j.ab.2005.06.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitative reverse transcription polymerase chain reaction (qRT-PCR) conducted in real time is a powerful tool for measuring messenger RNA (mRNA) levels in biological samples. Multiplex PCR is defined as the simultaneous amplification of two or more DNA (cDNA) targets in a single reaction vessel and may be carried out only using uniquely labeled probes for each target. Up to four genes can be detected in a multiplex 5' nuclease assay when using the appropriate instrument and the right combination of fluorophores. One of the more important advantages of multiplexing is a reduced sample requirement, which is especially important when sample material is scarce. Additional benefits are saving time on reaction setup and lower cost compared to singleplex reactions. Although multiplexing has several advantages over singleplex qRT-PCR, limited work has been done to show its feasibility. Few publications on four-color multiplex qRT-PCR have been reported, and to our knowledge no work has been done to explore the assay's limitations. In this paper, we report the first in-depth analysis of a four-gene multiplex qRT-PCR. To achieve a better understanding of the potential limitations of the qRT-PCR assay, we used in vitro transcribed RNA derived from four human genes. To emulate gene expression experiments, we developed a model system in which the in vitro transcripts were spiked with plant total RNA. This model allowed us to develop an artificial system closely resembling differential gene expression levels varying up to a million fold. We identified a single "universal" reaction condition that enabled optimal amplification in real time of up to four genes over a wide range of template concentrations. This Study shows that multiplexing is a feasible approach applicable to most qRT-PCR assays performed with total RNA, independent of the expression levels of the genes under scrutiny. (C) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:33 / 42
页数:10
相关论文
共 19 条
  • [1] Bernard PS, 2002, CLIN CHEM, V48, P1178
  • [2] Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems
    Bustin, SA
    [J]. JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2002, 29 (01) : 23 - 39
  • [3] DELETION SCREENING OF THE DUCHENNE MUSCULAR-DYSTROPHY LOCUS VIA MULTIPLEX DNA AMPLIFICATION
    CHAMBERLAIN, JS
    GIBBS, RA
    RANIER, JE
    NGUYEN, PN
    CASKEY, CT
    [J]. NUCLEIC ACIDS RESEARCH, 1988, 16 (23) : 11141 - 11156
  • [4] An overview of real-time quantitative PCR: Applications to quantify cytokine gene expression
    Giulietti, A
    Overbergh, L
    Valckx, D
    Decallonne, B
    Bouillon, R
    Mathieu, C
    [J]. METHODS, 2001, 25 (04) : 386 - 401
  • [5] Development and assessment of a quantitative reverse transcription-PCR assay for simultaneous measurement of four amplicons
    Grace, MB
    McLeland, CB
    Gagliardi, SJ
    Smith, JM
    Jackson, WE
    Blakely, WF
    [J]. CLINICAL CHEMISTRY, 2003, 49 (09) : 1467 - 1475
  • [6] Multiplex PCR: Critical parameters and step-by-step protocol
    Henegariu, O
    Heerema, NA
    Dlouhy, SR
    Vance, GH
    Vogt, PH
    [J]. BIOTECHNIQUES, 1997, 23 (03) : 504 - 511
  • [7] KINETIC PCR ANALYSIS - REAL-TIME MONITORING OF DNA AMPLIFICATION REACTIONS
    HIGUCHI, R
    FOCKLER, C
    DOLLINGER, G
    WATSON, R
    [J]. BIO-TECHNOLOGY, 1993, 11 (09): : 1026 - 1030
  • [8] DETECTION OF SPECIFIC POLYMERASE CHAIN-REACTION PRODUCT BY UTILIZING THE 5'-]3' EXONUCLEASE ACTIVITY OF THERMUS-AQUATICUS DNA-POLYMERASE
    HOLLAND, PM
    ABRAMSON, RD
    WATSON, R
    GELFAND, DH
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1991, 88 (16) : 7276 - 7280
  • [9] The PCR plateau phase - towards an understanding of its limitations
    Kainz, P
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-GENE STRUCTURE AND EXPRESSION, 2000, 1494 (1-2): : 23 - 27
  • [10] Technology platforms for pharmacogenomic diagnostic assays
    Koch, WH
    [J]. NATURE REVIEWS DRUG DISCOVERY, 2004, 3 (09) : 749 - 761