Quantitative analysis of trace element abundances in glasses and minerals: a comparison of laser ablation inductively coupled plasma mass spectrometry, solution inductively coupled plasma mass spectrometry, proton microprobe and electron microprobe data

被引:213
作者
Norman, MD [1 ]
Griffin, WL
Pearson, NJ
Garcia, MO
O'Reilly, SY
机构
[1] Macquarie Univ, Sch Earth Sci, ARC Natl Key Ctr Geochem Evolut & Metallogeny Con, Sydney, NSW 2109, Australia
[2] CSIRO, N Ryde, NSW 2113, Australia
[3] Univ Hawaii, Dept Geol & Geophys, Hawaii Ctr Volcanol, Honolulu, HI 96822 USA
关键词
trace element analysis; glass; mineral; laser ablation inductively coupled plasma mass spectrometry; solution inductively coupled plasma mass spectrometry; proton microprobe analysis; electron microprobe analysis;
D O I
10.1039/a707972i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Many geological, environmental and industrial applications can be enhanced through integrated microbeam and bulk geochemical determinations of major and trace element concentrations, Advantages of in situ microanalysis include minimal sample preparation, low blanks, information about the spatial distribution of compositional characteristics and the ability to avoid microscopic inclusions of foreign material, In this paper we compare trace element data obtained by laser ablation ICP-MS, solution ICP-MS, electron microprobe analysis and proton microprobe analysis for a variety of silicate glasses and minerals, New determinations for 36 trace elements in BCR-2G, a microbeam glass standard, are presented. Results obtained by the various microbeam and solution methods agree well for concentrations ranging over several orders of magnitude. Replicate analyses of BCR-2G demonstrate an analytical precision of 2-8% relative (1 sigma) for all elements by laser ablation ICP-MS and less than or equal to 3% by solution ICP-MS, except for Li (5%), These data emphasize the utility of laser ablation ICP-MS as a quantitative microbeam technique capable of rapid, precise determinations of sub-ppm trace element abundances in a variety of targets.
引用
收藏
页码:477 / 482
页数:6
相关论文
共 21 条
[1]  
ALBIN E, 1996, METEORITICS, V31, pA5
[2]  
[Anonymous], 1995, Microprobe Techniques in the Earth Sciences
[3]  
Dressler B.O., 1994, Large Impact Structures and Planetary Evolution, P133
[4]   A simple method for the precise determination of >=40 trace elements in geological samples by ICPMS using enriched isotope internal standardisation [J].
Eggins, SM ;
Woodhead, JD ;
Kinsley, LPJ ;
Mortimer, GE ;
Sylvester, P ;
McCulloch, MT ;
Hergt, JM ;
Handler, MR .
CHEMICAL GEOLOGY, 1997, 134 (04) :311-326
[5]  
GARCIA MO, IN PRESS B VOLCANOL
[6]  
GRIFFIN WL, 1998, AM GEOPHYS UNION GEO, V26, P1
[7]   Pulsed glow discharge time-of-flight mass spectrometry [J].
Harrison, WW ;
Hang, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :835-840
[8]   DEVELOPMENTS IN PLASMA SOURCE-MASS SPECTROMETRY [J].
HIEFTJE, GM ;
VICKERS, GH .
ANALYTICA CHIMICA ACTA, 1989, 216 (1-2) :1-24
[9]  
IRELAND TR, 1995, ADV ANAL GEOCHEM, V2, P1
[10]  
JACKSON SE, 1992, CAN MINERAL, V30, P1049