A noninvasive method to estimate arterial impedance by means of assessment of local diameter change and the local center-line blood flow velocity using ultrasound

被引:34
作者
Brands, PJ
Hoeks, APG
Rutten, MCM
Reneman, RS
机构
[1] EINDHOVEN UNIV TECHNOL,DEPT MECH ENGN,NL-5600 MB EINDHOVEN,NETHERLANDS
[2] UNIV LIMBURG,CARDIOVASC RES INST MAASTRICHT,DEPT PHYSIOL,NL-6200 MD MAASTRICHT,NETHERLANDS
关键词
pulsed ultrasound; RF cross-correlation; signal processing; vascular impedance; vessel wall displacement;
D O I
10.1016/0301-5629(96)00082-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Vascular impedance is defined as the ratio between the frequency components of the local blood pressure waveform and those of the local blood volume flow waveform, Assessment of vascular impedance is, for example, important to study heart load and distal vascular bed vasomotricity, However, only a few studies on vascular impedance have been performed in humans because pulsatile pressure and volume flow waveforms, simultaneously recorded at the same location, are difficult to obtain noninvasively, The noninvasive assessment of arterial impedance as described in this study is based on the replacement of the pressure waveform by the distension (change in diameter) waveform and the volume how waveform by the center-line blood flow velocity waveform, Both waveforms can simultaneously and accurately be assessed by means of pulsed ultrasound, It will be shown that, depending on the Womersley number, the volume flow waveform may be replaced by the center-line blood flow velocity waveform for a given frequency range and that the pressure waveform may be replaced by the distension waveform for a wide frequency range, The validation of the proposed ultrasound method was performed through an in vitro study in a flow model with a distensible tube terminated with a hydraulic load (modified windkessel model), It is shown that, in vitro, the proposed method gives the same results as the local spectral pressure-flow relationship.
引用
收藏
页码:895 / 905
页数:11
相关论文
共 20 条
[1]   SITE-DEPENDENT EFFECTS OF INCREASES IN PLACENTAL VASCULAR-RESISTANCE ON THE UMBILICAL ARTERIAL VELOCITY WAVEFORM IN FETAL SHEEP [J].
ADAMSON, SL ;
MORROW, RJ ;
LANGILLE, BL ;
BULL, SB ;
RITCHIE, JWK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (01) :19-27
[2]   VASCULAR-RESISTANCE QUANTIFICATION IN HIGH-FLOW RESISTANCE AREAS USING THE DOPPLER METHOD [J].
ARBEILLE, P ;
BERSON, M ;
ACHAIBOU, F ;
BODARD, S ;
LOCATELLI, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (03) :321-328
[3]   PRESSURE-FLOW RELATIONS IN DOG ARTERIES [J].
ATTINGER, EO ;
SUGAWARA, H ;
NAVARRO, A ;
RICCETTO, A ;
MARTIN, R .
CIRCULATION RESEARCH, 1966, 19 (02) :230-+
[4]   A NONINVASIVE METHOD TO ESTIMATE WALL SHEAR RATE USING ULTRASOUND [J].
BRANDS, PJ ;
HOEKS, APG ;
HOFSTRA, L ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (02) :171-185
[5]   DETERMINATION OF TISSUE MOTION VELOCITY BY CORRELATION INTERPOLATION OF PULSED ULTRASONIC ECHO SIGNALS [J].
DEJONG, PGM ;
ARTS, T ;
HOEKS, APG ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1990, 12 (02) :84-98
[6]   AORTIC PULSE-WAVE VELOCITY, ELASTICITY, AND COMPOSITION IN A NONHUMAN PRIMATE MODEL OF ATHEROSCLEROSIS [J].
FARRAR, DJ ;
GREEN, HD ;
BOND, MG ;
WAGNER, WD ;
GOBBEE, RA .
CIRCULATION RESEARCH, 1978, 43 (01) :52-62
[7]   MEASUREMENT OF VISCOELASTIC PROPERTIES OF ARTERIES IN LIVING DOG [J].
GOW, BS ;
TAYLOR, MG .
CIRCULATION RESEARCH, 1968, 23 (01) :111-+
[8]  
Hoeks A. P. G., 1995, Archives of Acoustics, V20, P65
[9]   COMPARISON OF THE PERFORMANCE OF THE RF CROSS-CORRELATION AND DOPPLER AUTOCORRELATION TECHNIQUE TO ESTIMATE THE MEAN VELOCITY OF SIMULATED ULTRASOUND SIGNALS [J].
HOEKS, APG ;
ARTS, TGJ ;
BRANDS, PJ ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (09) :727-740
[10]  
MAULIK D, 1989, J ULTRAS MED, V8, P177