Picoliter sample preparation in MALDI-TOF MS using a micromachined silicon flow-through dispenser

被引:104
作者
Önnerfjord, P
Nilsson, J
Wallman, L
Laurell, T
Marko-Varga, G
机构
[1] Astro Draco AB, Bioanalyt Chem Preclin Res & Dev, S-22100 Lund, Sweden
[2] Univ Lund, Dept Analyt Chem, S-22100 Lund, Sweden
[3] Lund Inst Technol, Dept Elect Measurements, S-22100 Lund, Sweden
关键词
D O I
10.1021/ac980207z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a picoliter sample preparation technique utilizing the now-through principle, allowing on-line coupling of chromatographic systems to be made. The work was performed in order to investigate the characteristics and the physicochemical properties of the sample preparation using typical mobile phase conditions from mu-CLC (column liquid chromatography) separations, The device presented here is a pressure pulse-driven dispenser, formed by two silicon structures processed by conventional micromachining. The pressure pulse is generated in the now-through channel by a piezoceramic element, Depending on the orifice size, the droplets ejected range between 30 and 200 pL. The maximum ejection frequency is 500 Hz, limited by resonances within the unit. A pyramid-shaped nozzle improves the directivity of the droplets since it reduces the wetting of the orifice front surface area. The risk of particles sticking close to the orifice is also minimized. The analyses of the deposited sample spots were carried out on a matrix-assisted laser desorption/ionization time-of-night mass spectrometer with delayed extraction. It was possible to detect attomole amounts (159-248 amol) of various proteins (cytochrome c, ribonuclease A; lysozyme, and myoglobin) from a single droplet of matrix:analyte 1:1 (drop volume approximate to 110 pL). Additionally, it was found that sample enrichment could be carried out using multiple depositions on the same spot; i.e., 31 nM of insulin was easily detected when more than four depositions were made on the same spot, while no detection was possible without sample enrichment. Size optimization of the MALDI sample spot gave target zones of 100-500-mu m diameter that matched the size of the laser focal point and resulted in a considerably increased sample throughput.
引用
收藏
页码:4755 / 4760
页数:6
相关论文
共 22 条
[1]  
Allmaier G, 1997, RAPID COMMUN MASS SP, V11, P1567, DOI 10.1002/(SICI)1097-0231(199709)11:14<1567::AID-RCM32>3.0.CO
[2]  
2-0
[3]  
CHUONRUO W, 1993, SENS ACTUATORS A, V35, P181
[4]   Graphite/liquid mixed matrices for laser desorption/ionization mass spectrometry [J].
Dale, MJ ;
Knochenmuss, R ;
Zenobi, R .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3321-3329
[5]  
EHRFELD W, 1998, MICROREACTION TECHNO
[6]   MALDI MS and strategies for protein analysis [J].
Fenselau, C .
ANALYTICAL CHEMISTRY, 1997, 69 (21) :A661-A665
[7]   Matrix-assisted laser desorption ionisation mass spectrometry of oligosaccharides and glycoconjugates [J].
Harvey, DJ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 720 (1-2) :429-446
[8]   ATTOMOLE DETECTION OF PROTEINS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY WITH THE USE OF PICOLITRE VIALS [J].
JESPERSEN, S ;
NIESSEN, WMA ;
TJADEN, UR ;
VANDERGREEF, J ;
LITBORN, E ;
LINDBERG, U ;
ROERAADE, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (08) :581-584
[9]   Matrix-assisted laser desorption ionization MS: A progress report [J].
Karas, M .
BIOCHEMICAL SOCIETY TRANSACTIONS, 1996, 24 (03) :897-900
[10]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301