Validation of high gradient magnetic field based drug delivery to magnetizable implants under flow

被引:71
作者
Forbes, Zachary G. [1 ]
Yellen, Benjamin B. [1 ,2 ]
Halverson, Derek S. [4 ]
Fridman, Gregory [3 ,4 ]
Barbee, Kenneth A. [3 ]
Friedman, Gary
机构
[1] Drexel Univ, Coll Med, Dept Surg, Philadelphia, PA 19102 USA
[2] Duke Univ, Dept Mech Engn & Mat Sci, Durham, NC 27708 USA
[3] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[4] Drexel Univ, Dept Elect & Comp Engn, Philadelphia, PA 19104 USA
基金
美国国家科学基金会;
关键词
magnetic drug delivery; magnetic separation cardiovascular disease; stents;
D O I
10.1109/TBME.2007.899347
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The drug-eluting stent's increasingly frequent occurrence late stage thrombosis have created a need for new strategies for intervention in coronary artery disease. This paper demonstrates further development of our minimally invasive, targeted drug delivery system that uses induced magnetism to administer repeatable and patient specific dosages of therapeutic agents to specific sites in the human body. Our first, aim is the use of magnetizable stents for the prevention and treatment of coronary restenosis; however, future applications include the targeting of tumors, vascular defects, and other localized pathologies. Future doses can be administered to the same site by intravenous injection. This implant-based drug delivery system functions by placement of a weakly magnetizable stent or implant at precise locations in the cardiovascular system, followed by the delivery of magnetically susceptible drug carriers. The stents are capable of applying high local magnetic field gradients within the body, while only exposing the body to a modest external field. The local gradients created within the blood vessel create the forces needed to attract and hold drug-containing magnetic nanoparticles at the implant site. Once these particles are captured, they are capable of delivering therapeutic agents. such as antineoplastics, radioactivity, or biological cells.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 26 条
[1]
Babincová M, 2001, Z NATURFORSCH C, V56, P909
[2]
HUMAN SENSITIVITY TO WEAK MAGNETIC-FIELDS [J].
BELL, GB ;
MARINO, AA ;
CHESSON, AL ;
STRUVE, FA .
LANCET, 1991, 338 (8781) :1521-1522
[3]
Dijkmans P A, 2004, Eur J Echocardiogr, V5, P245, DOI 10.1016/j.euje.2004.02.001
[4]
Electrodeposited Co-Ni alloys for MEMS [J].
Duch, M ;
Esteve, J ;
Gómez, E ;
Pérez-Castillejos, R ;
Vallés, E .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2002, 12 (04) :400-405
[5]
AN ALTERNATING-GRADIENT MAGNETOMETER [J].
FLANDERS, PJ .
JOURNAL OF APPLIED PHYSICS, 1988, 63 (08) :3940-3945
[6]
FLORES GA, 2002, EUR CELLS MAT S2, V3, P9
[7]
An approach to targeted drug delivery based on uniform magnetic fields [J].
Forbes, ZG ;
Yellen, BB ;
Barbee, KA ;
Friedman, G .
IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (05) :3372-3377
[8]
PARTICLE BUILDUP ON SINGLE SPHERES IN HGMS [J].
FRIEDLAENDER, FJ ;
GERBER, R ;
HENKEL, HP ;
BIRSS, RR .
IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (06) :2804-2806
[9]
PARTICLE MOTION NEAR AND CAPTURE ON SINGLE SPHERES IN HGMS [J].
FRIEDLAENDER, FJ ;
GERBER, R ;
KURZ, W ;
BIRSS, RR .
IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (06) :2801-2803
[10]
Gallo JM, 1997, CANCER RES, V57, P3063