Comparisons of metal leachability for various wastes by extraction and leaching methods

被引:114
作者
Chang, EE
Chiang, PC
Lu, PH
Ko, YW
机构
[1] Taipei Med Univ, Dept Biochem, Taipei 105, Taiwan
[2] Natl Taiwan Univ, Grad Inst Environm Engn, Taipei 106, Taiwan
[3] Da Yeh Univ, Dept Environm Engn, Changhua 515, Taiwan
关键词
American Society for Testing and Materials method; extraction procedure; lysimetry test; toxicity characteristic leaching procedures;
D O I
10.1016/S0045-6535(01)00002-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this research was to evaluate three extraction tests, i.e., toxicity characteristic leaching procedures (TCLP), extraction procedure (EP), and American Society for Testing and Materials (ASTM) methods, for their ability to extract metals in chemical sludge and incineration bottom ash, in terms of the precision of analytical results. Typical chemical sludges, including the electroplating and dye-stuff sludges, the municipal solid waste incineration bottom ash, the leather debris, and the steel-mill bottom residue containing Cd, Cr, Cu, Pb, and Zn were prepared for the lysimetry test (dynamic testing) to compare with the extraction results. Results show that for bottom residue and dye-stuff sludge, the concentration of metal leached was almost the same between the lysimetry leaching and the TCLP tests. The metal concentration followed the order: TCLP approximate to EP > ASTM. TCLP and EP exhibited almost the same relative standard deviation (RSD) value. Therefore, the results of the TCLP tests for bottom residue and dye-stuff sludge, which have a low metal content and alkalinity, can be used to estimate the metal concentration leached by typical acid rain in Taiwan; whereas the ASTM extraction test may be a better indicator of the lysimetry test. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 9 条
  • [1] *ASTM, 1981, STAND METH CHEM AN H
  • [2] *ASTM, 1985, D398785 ASTM, P24
  • [3] BISHOP PL, 1986, P 18 MID IND WAST C, P236
  • [4] BLACKBURN WB, 1988, EPA600487045 TCLP
  • [5] FAELLMAN AM, 1997, ENVIRON SCI TECHNOL, V31, P735
  • [6] LESS THAN OBVIOUS - STATISTICAL TREATMENT OF DATA BELOW THE DETECTION LIMIT
    HELSEL, DR
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (12) : 1766 - 1774
  • [7] Toxicity characteristic leaching procedure fails to extract oxoanion-forming elements that are extracted by municipal solid waste leachates
    Hooper, K
    Iskander, M
    Sivia, G
    Hussein, F
    Hsu, J
    Deguzman, M
    Odion, Z
    Ilejay, Z
    Sy, F
    Petreas, M
    Simmons, B
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (23) : 3825 - 3830
  • [8] U.S. Environmental Protection Agency, 1986, TEST METH EV SOL WAS, V3rd
  • [9] 1986, FED REG 1107, V51, P216