Mercuracarborand "anti-crown ether"-based chloride sensitive liquid/polymeric membrane electrodes

被引:90
作者
Badr, IHA [1 ]
Diaz, M [1 ]
Hawthorne, MF [1 ]
Bachas, LG [1 ]
机构
[1] Univ Kentucky, Dept Chem, Lexington, KY 40506 USA
关键词
D O I
10.1021/ac980896e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly sensitive and selective chloride liquid/polymeric membrane electrodes are described that employ [9]mercuracarborand-3 (MC3), a neutral preorganized macrocyclic Lewis acid, as the anion carrier, MC3-based chloride-sensitive membrane electrodes, doped with different mole percentages of cationic additives (5, 10, and 60 mol % tridodecylmethylammonium chloride) relative to the amount of the. carrier, exhibit enhanced potentiometric selectivity for chloride over other anions, including more lipophilic anions such as perchlorate, nitrate, and thiocyanate, In addition, the selectivity coefficients obtained are shown to meet the requirement for clinical applications. The obtained selectivity pattern is shown to correlate very well with Hg-199 NMR titrations of MC3 with various anions, performed in organic solvents. Optimized membrane electrodes show a near-Nernstian response toward chloride over a wide concentration range and have micromolar detection limits. MCS-based chloride sensors show a fast response time (in the order of few seconds), as well as short recovery time. The developed mercuracarborand-based sensors do not practically respond to pH changes over the pH range of 2.5-7.0, Response characteristics (e.g., detection limit, linear range, response slope, and selectivity) of the [9]mercuracarborand-3 based chloride sensors remain essentially the same over a period of similar to 2 months, reflecting remarkable stability and well-defined chemistry of the macrocyclic Lewis acid ionophore.
引用
收藏
页码:1371 / 1377
页数:7
相关论文
共 49 条
  • [1] POTENTIOMETRIC ANION SELECTIVITY OF POLYMER MEMBRANES DOPED WITH PALLADIUM ORGANOPHOSPHINE COMPLEX
    BADR, IHA
    MEYERHOFF, ME
    HASSAN, SSM
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (15) : 2613 - 2618
  • [2] BADR IHA, 1995, ANAL CHIM ACTA, V310, P211, DOI 10.1016/0003-2670(95)00154-R
  • [3] ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY
    BAKKER, E
    MALINOWSKA, E
    SCHILLER, RD
    MEYERHOFF, ME
    [J]. TALANTA, 1994, 41 (06) : 881 - 890
  • [4] MERCURATION OF ORTHO-CARBORANES AND META-CARBORANES
    BREGADZE, VI
    KAMPEL, VT
    GODOVIKOV, NN
    [J]. JOURNAL OF ORGANOMETALLIC CHEMISTRY, 1976, 112 (03) : 249 - 251
  • [5] Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    Buhlmann, P
    Pretsch, E
    Bakker, E
    [J]. CHEMICAL REVIEWS, 1998, 98 (04) : 1593 - 1687
  • [6] EMF RESPONSE OF NEUTRAL-CARRIER BASED ION-SENSITIVE FIELD-EFFECT TRANSISTORS WITH MEMBRANES FREE OF IONIC SITES
    BUHLMANN, P
    YAJIMA, S
    TOHDA, K
    UMEZAWA, Y
    [J]. ELECTROCHIMICA ACTA, 1995, 40 (18) : 3021 - 3027
  • [7] INFLUENCE OF PORPHYRIN STRUCTURE ON ANION SELECTIVITIES OF MANGANESE(III) PORPHYRIN BASED MEMBRANE ELECTRODES
    CHANIOTAKIS, NA
    CHASSER, AM
    MEYERHOFF, ME
    GROVES, JT
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (02) : 185 - 188
  • [8] CHEMICALLY-MODIFIED FIELD-EFFECT TRANSISTORS - THE EFFECT OF ION-PAIR ASSOCIATION ON THE MEMBRANE-POTENTIALS
    COBBEN, PLHM
    EGBERINK, RJM
    BOMER, JG
    BERGVELD, P
    REINHOUDT, DN
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 368 (1-2): : 193 - 208
  • [9] CRAM DJ, 1996, MONOGRAPHS SUPRAMOLE, V4
  • [10] ANION-SELECTIVE ELECTRODES BASED ON A HYDROPHOBIC VITAMIN-B12 DERIVATIVE
    DAUNERT, S
    BACHAS, LG
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (05) : 499 - 503