Continuous-flow separation and pre-concentration coupled on-line to solid-surface fluorescence spectroscopy for the simultaneous determination of o-phenylphenol and thiabendazole

被引:21
作者
Reyes, JFG [1 ]
Martínez, EJL [1 ]
Barrales, POP [1 ]
Díaz, AM [1 ]
机构
[1] Univ Jaen, Fac Expt Sci, Dept Phys & Analyt Chem, Jaen 23071, Spain
关键词
flow injection; fluorescence; pesticides; o-phenylphenol; thiabendazole;
D O I
10.1007/s00216-003-2249-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel and single flow-injection system combined with solid-surface fluorescence detection is proposed in this work for the resolution of a mixture of two widely used pesticides (o-phenylphenol and thiabendazole). The continuous-flow methodology is based on the implementation of on-line pre-concentration and separation of both analytes on the surface of C-18 silica gel beads placed just inside the flow cell, implemented with gel-phase fluorimetric multi-wavelength detection (using 305/358 and 250/345 nm as excitation/emission wavelengths for thiabendazole and o-phenylphenol, respectively). The separation of the pesticides was possible owing to the different retention/desorption kinetics of their interactions with the solid support in the zone where the stream impinges on the solid material. No previous separation of the analytes before they reach the flow cell is needed thereby simplifying substantially both the procedure and the manifold. By using a sample volume of 2,600 muL, the system was calibrated in the range 0.5-16 and 5-120 ng mL(-1) with detection limits of 0.09 and 0.60 ng mL(-1) for thiabendazole and o-phenylphenol, respectively. The RSD values (n=10) were about 1% for both analytes. The proposed methodology was applied to environmental water samples and also to various commercial pesticide formulations containing both analytes. Recovery percentages were 97-103% and 98-102% for thiabendazole and o-phenylphenol, respectively.
引用
收藏
页码:429 / 437
页数:9
相关论文
共 29 条
[1]   Molecular fluorescence, phosphorescence, and chemiluminescence spectrometry [J].
Agbaria, RA ;
Oldham, PB ;
McCarroll, M ;
McGown, LB ;
Warner, IM .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :3952-3962
[2]  
BARCELO D, 1993, ENV ANAL TECHNIQUES
[3]   Optical multiple-analyte immunosensor for water pollution control [J].
Barzen, C ;
Brecht, A ;
Gauglitz, G .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (04) :289-295
[4]   DETERMINATION OF THIABENDAZOLE RESIDUES IN WATERS BY SOLID-PHASE SPECTROFLUOROMETRY [J].
CAPITAN, F ;
ALONSO, E ;
AVIDAD, R ;
CAPITANVALLVEY, LF ;
VILCHEZ, JL .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :1336-1339
[5]   Solid-phase spectrophosphorimetric determination of the pesticide o-phenylphenol in water and vegetables [J].
Capitán-Vallvey, LF ;
Deheidel, MKA ;
Avidad, R .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (05) :685-691
[6]   Micellar-stabilized room-temperature phosphorimetric determination of the fungicide thiabendazole in canned pineapple samples [J].
Carretero, AS ;
Blanco, CC ;
Fernandez, RE ;
Gutierrez, AF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (05) :605-608
[7]   Fluorimetric analysis of pesticides: Methods, recent developments and applications [J].
Coly, A ;
Aaron, JJ .
TALANTA, 1998, 46 (05) :815-843
[8]   Simultaneous determination of fluorophores with overlapped spectra by sequential injection analysis coupled to variable angle scanning fluorescence spectrometry and multivariate linear regression algorithms [J].
de Armas, G ;
Miró, M ;
Estela, JM ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 2002, 471 (02) :173-186
[9]  
de la Riva BS, 1999, ANAL CHIM ACTA, V395, P1
[10]   UV spectrophotometric flow-through multiparameter sensor for the simultaneous determination of acetaminophen, acetylsalicylic acid, and caffeine [J].
Vidal, AD ;
Reyes, JFG ;
Barrales, PO ;
Díaz, AM .
ANALYTICAL LETTERS, 2002, 35 (15) :2433-2447