Automated office versus home measurement of blood pressure in the assessment of morning hypertension

被引:8
作者
Andreadis, Emmanuel A. [1 ]
Angelopoulos, Epameinondas T. [1 ]
Tsakanikas, Athanasios P. [1 ]
Agaliotis, Gerasimos D. [1 ]
Kravvariti, Sofia D. [1 ]
Mousoulis, George P. [1 ]
机构
[1] Evangelismos Gen Hosp, Dept Internal Med 3, Athens 11521, Greece
关键词
ambulatory blood pressure; automated office blood pressure; home blood pressure; morning hypertension; EUROPEAN-SOCIETY; RISK; RECOMMENDATIONS; OHASAMA;
D O I
10.1097/MBP.0b013e3283503760
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To compare the quality and accuracy of morning blood pressure (BP) readings as taken by automated office BP (AOBP) and morning home BP (mHBP) techniques using morning ambulatory BP (mABP) measurements as the gold standard. Methods A total of 139 individuals were included, 70 men and 69 women, mean age 53 +/- 13 years. The average AOBP readings as measured using a Microlife Watch BP office device taking triplicate automated simultaneous readings of both arms were compared with mHBP monitored on 6 routine days, using a validated automated electronic device. Both modalities were also compared with the ambulatory readings of the 3 h of waking (mABP3h). Results The AOBP values were slightly higher than the mABP3h (mean difference 8.2 mmHg, 95% limits of agreement, -18.8 to 35.2 mmHg for the systolic BP and mean difference 4.3 mmHg, 95% limits of agreement, -15.3 to 23.9 mmHg for the diastolic BP). Systolic and diastolic AOBP readings correlated with mABP3h (r=0.66, P=0.001 and r=0.64, P=0.001, respectively). Agreement was fair between AOBP and mHBP in the detection of morning hypertensive patients (agreement 70%, kappa=0.32) as compared with AOBP and mABP3h (agreement 67%, kappa=0.32) and mHBP and mABP3h (agreement 65%, kappa=0.31). Conclusion The AOBP technique could replace mHBP monitoring in the assessment of morning BP, as it provides comparable data in relation to the awake ambulatory BP. Given the simplicity of this method, it could be more readily applied in a larger number of individuals. Blood Press Monit 17:24-34 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:24 / 34
页数:11
相关论文
共 22 条
  • [1] Automated Office Blood Pressure and 24-h Ambulatory Measurements are Equally Associated With Left Ventricular Mass Index
    Andreadis, Emmanuel A.
    Agaliotis, Gerasimos D.
    Angelopoulos, Epameinondas T.
    Tsakanikas, Athanasios P.
    Chaveles, Loannis A.
    Mousoulis, George P.
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2011, 24 (06) : 661 - 666
  • [2] [Anonymous], 1987, AM NAT STAND EL AUT
  • [3] Prediction of stroke by home "morning" versus "evening" blood pressure values - The Ohasama study
    Asayama, Kei
    Ohkubo, Takayoshi
    Kikuya, Masahiro
    Obara, Taku
    Metoki, Hirohito
    Inoue, Ryusuke
    Hara, Azusa
    Hirose, Takuo
    Hoshi, Haruhisa
    Hashimoto, Junichiro
    Totsune, Kazuhito
    Satoh, Hiroshi
    Imai, Yutaka
    [J]. HYPERTENSION, 2006, 48 (04) : 737 - 743
  • [4] Ambulatory blood pressure monitoring versus selfmeasurement of blood pressure at home: correlation with target organ damage
    Gaborieau, Valerie
    Delarche, Nicolas
    Gosse, Philippe
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 (10) : 1919 - 1927
  • [5] Usefulness of home blood pressure is measurement in the morning in type 2 diabetic patients
    Kamoi, K
    Miyakoshi, M
    Soda, S
    Kaneko, S
    Nakagawa, O
    [J]. DIABETES CARE, 2002, 25 (12) : 2218 - 2223
  • [6] Early morning hypertension: what does it contribute to overall cardiovascular risk assessment?
    Kario, Kazuomi
    White, William B.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2008, 2 (06) : 397 - 402
  • [7] Prognostic significance of night-time, early morning, and daytime blood pressures on the risk of cerebrovascular and cardiovascular mortality: the Ohasama Study
    Metoki, Hirohito
    Ohkubo, Takayoshi
    Kikuya, Masahiro
    Asayama, Kei
    Obara, Taku
    Hara, Azusa
    Hirose, Takuo
    Hashimoto, Junichiro
    Totsune, Kazuhito
    Hoshi, Haruhisa
    Satoh, Hiroshi
    Imai, Yutaka
    [J]. JOURNAL OF HYPERTENSION, 2006, 24 (09) : 1841 - 1848
  • [8] Myers Martin G, 2007, J Clin Hypertens (Greenwich), V9, P267
  • [9] Comparison between an automated and manual sphygmomanometer in a population survey
    Myers, Martin G.
    Mcinnis, Natalie H.
    Fodor, George J.
    Leenen, Frans H. H.
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2008, 21 (03) : 280 - 283
  • [10] Measurement of Blood Pressure in the Office Recognizing the Problem and Proposing the Solution
    Myers, Martin G.
    Godwin, Marshall
    Dawes, Martin
    Kiss, Alexander
    Tobe, Sheldon W.
    Kaczorowski, Janusz
    [J]. HYPERTENSION, 2010, 55 (02) : 195 - 200