Diagnosis of coronary artery disease in patients with permanent cardiac pacemaker by dobutamine stress echocardiography or exercise thallium-201 myocardial tomography

被引:12
作者
Ciaroni, S [1 ]
Bloch, A [1 ]
Albrecht, L [1 ]
Vanautryve, B [1 ]
机构
[1] Hop Tour, Serv Cardiol, Meyrin, Switzerland
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2000年 / 17卷 / 07期
关键词
dobutamine echocardiography; thallium tomography; cardiac pacemaker;
D O I
10.1046/j.1540-8175.2000.00675.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated the use of dobutamine stress echocardiography and exercise thallium-201 myocardial computed tomography (CT) in the diagnosis of coronary artery disease (CAD) in patients with permanent transvenous pacemaker with the electrode implanted in the right ventricle (RV). Twenty-nine consecutive patients with pacemaker underwent dobutamine stress echocardiography, exercise thallium-201 myocardial CT, and coronary arteriography over a period of 8 +/- 1 days. None of these patients had suffered a myocardial infarction (MI). The cardiac rhythm of every patient was electrically paced during echocardiography and tomography. Sixteen. (55%) patients showed CAD on angiography (stenosis greater than or equal to 50% of the luminal diameter of a major epicardial vessel). The detection sensitivity for CAD was 94% for the tomography and 88% for the echocardiography (P = NS). The difference between the sensitivities of the true techniques in detecting CAD based on the affected coronary artery was not statistically significant. Of the 13 patients without CAD, tomography showed a positive result in nine cases, i.e., a specificity of 31%, whereas echocardiography showed a positive result in only one case, i.e., a specificity of 92% (P < 0.01). Exercise thallium-201 myocardial computed tomography produces an increased rate of false-positive results in patients with permanent transvenous cardiac pacemaker (PCP) implanted in the right ventricle (RV). Dobutamine stress echocardiography can. thus be used to reduce considerably the level of false-positive results in these patients and still retain, a detection sensitivity for CAD equal to that of myocardial tomography.
引用
收藏
页码:675 / 679
页数:5
相关论文
共 19 条
[1]   PARADOXICAL MOTION OF INTERVENTRICULAR SEPTUM IN LEFT-BUNDLE BRANCH-BLOCK [J].
ABBASI, AS ;
EBER, LM ;
MACALPIN, RN ;
KATTUS, AA .
CIRCULATION, 1974, 49 (03) :423-427
[2]  
Bourdillon PD, 1989, J AM SOC ECHOCARDIOG, V2, P398
[3]   IMPROVED SPECIFICITY OF MYOCARDIAL TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN PATIENTS WITH LEFT-BUNDLE-BRANCH BLOCK BY DIPYRIDAMOLE [J].
BURNS, RJ ;
GALLIGAN, L ;
WRIGHT, LM ;
LAWAND, S ;
BURKE, RJ ;
GLADSTONE, PJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (05) :504-508
[4]   QUANTITATIVE MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC IMAGING - QUO-VADIS - (WHERE DO WE GO FROM HERE) [J].
GARCIA, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 1994, 1 (01) :83-93
[5]   Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography [J].
Geleijnse, ML ;
Fioretti, PM ;
Roelandt, JRTC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :595-606
[6]   FUNCTIONAL ABNORMALITIES IN ISOLATED LEFT-BUNDLE BRANCH-BLOCK - THE EFFECT OF INTERVENTRICULAR ASYNCHRONY [J].
GRINES, CL ;
BASHORE, TM ;
BOUDOULAS, H ;
OLSON, S ;
SHAFER, P ;
WOOLEY, CF .
CIRCULATION, 1989, 79 (04) :845-853
[7]   TL-201 SCINTIGRAPHY IN COMPLETE LEFT-BUNDLE BRANCH-BLOCK [J].
HIRZEL, HO ;
SENN, M ;
NUESCH, K ;
BUETTNER, C ;
PFEIFFER, A ;
HESS, OM ;
KRAYENBUEHL, HP .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (06) :764-769
[8]  
KOTLER TS, 1990, ANN INTERN MED, V113, P684, DOI 10.7326/0003-4819-113-9-684
[9]   Diagnosis of coronary artery disease by exercise thallium-201 tomography in patients with a right ventricular pacemaker [J].
Lakkis, NM ;
He, ZX ;
Verani, MS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (06) :1221-1225
[10]   DIAGNOSTIC-ACCURACY OF EXERCISE TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IN PATIENTS WITH LEFT-BUNDLE-BRANCH BLOCK [J].
LARCOS, G ;
GIBBONS, RJ ;
BROWN, ML .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (08) :756-760