The influence of calcium and/or phosphorus ion implantation on the structure and corrosion resistance of titanium

被引:28
作者
Krupa, D
Baszkiewicz, J
Kozubowski, J
Barcz, A
Sobczak, J
Bilinski, A
Rajchel, B
机构
[1] Warsaw Univ Technol, PL-02507 Warsaw, Poland
[2] Inst Electr Mat Technol, PL-02668 Warsaw, Poland
[3] Polish Acad Sci, Inst Phys Chem, PL-01224 Warsaw, Poland
[4] Inst Nucl Phys, PL-31342 Krakow, Poland
关键词
titanium; implantation; calcium; phosphorus; corrosion; biomaterials;
D O I
10.1016/S0042-207X(01)00263-9
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work presents the data on the corrosion resistance of titanium after Ca and/or P ion implantation with a dose of 10(17)/cm(2). The Ca-,(+) P+ ion energy was 25 keV. The corrosion resistance was examined by electrochemical methods in a simulated body fluid at a temperature of 37 degreesC. TEM was used to investigate the microstructure of implanted layers. The chemical composition of the surface layers was examined by XPS and SIMS. The results of electrochemical examination indicate that the P and Ca + P ion implantation into the surface of titanium increases its corrosion resistance. Samples implanted with Ca showed pitting corrosion during anodic polarization. The breakdown potentials were high (2.5-3 V). (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:715 / 719
页数:5
相关论文
共 9 条
[1]   ION-IMPLANTATION OF SURGICAL TI-6AL-4V FOR IMPROVED RESISTANCE TO WEAR-ACCELERATED CORROSION [J].
BUCHANAN, RA ;
RIGNEY, ED ;
WILLIAMS, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (03) :355-366
[2]   CHARACTERIZATION OF SURFACE-FILM FORMED ON TITANIUM IN ELECTROLYTE USING XPS [J].
HANAWA, T ;
OTA, M .
APPLIED SURFACE SCIENCE, 1992, 55 (04) :269-276
[3]   CALCIUM-PHOSPHATE NATURALLY FORMED ON TITANIUM IN ELECTROLYTE SOLUTION [J].
HANAWA, T ;
OTA, M .
BIOMATERIALS, 1991, 12 (08) :767-774
[4]  
HANAWA T, 1994, P S COMP BIOM IMPL S, P126
[5]   Effect of nitrogen-ion implantation on the corrosion resistance of OT-4-0 titanium alloy in 0.9% NaCl environment [J].
Krupa, D ;
Baszkiewicz, J ;
Jezierska, E ;
Mizera, J ;
Wierzchon, T ;
Barcz, A ;
Fillit, R .
SURFACE & COATINGS TECHNOLOGY, 1999, 111 (01) :86-91
[6]   Effect of carbon ion implantation on the structure and corrosion resistance of OT-4-0 titanium alloy [J].
Krupa, D ;
Jezierska, E ;
Baszkiewicz, J ;
Wierzchon, T ;
Barcz, A ;
Gawlik, G ;
Jagielski, J ;
Sobczak, JW ;
Bilinski, A ;
Larisch, B .
SURFACE & COATINGS TECHNOLOGY, 1999, 114 (2-3) :250-259
[7]   Effect of nitrogen ion implantation on the structure and corrosion resistance of OT-4-0 titanium alloy [J].
Krupa, D ;
Jezierska, E ;
Baszkiewicz, J ;
Kaminski, M ;
Wierzchon, T ;
Barcz, A .
SURFACE & COATINGS TECHNOLOGY, 1996, 79 (1-3) :240-245
[9]  
WILLIAMS JM, 1985, P ASM C APPL ION PLA, P141