Symmetry and reproducibility of kinematic parameters during various running techniques

被引:95
作者
Karamanidis, K [1 ]
Arampatzis, A [1 ]
Brüggemann, GP [1 ]
机构
[1] German Sport Univ Cologne, Inst Biomech, D-50933 Cologne, Germany
关键词
reliability; symmetry index; stride length; treadmill;
D O I
10.1249/01.MSS.0000069337.49567.F0
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: This study examined the validity of the assumption of lower-extremity kinematic parameter reproducibility and symmetry during running with different velocities and stride frequencies. Methods: Each of 12 female long-distance runners ran on a treadmill in combinations of three different velocities (2.5. 3.0, and 3.5 m.s(-1)) and three different stride frequencies (preferred and +/- 10% from preferred). The left and right sides of the athletes were filmed using video cameras placed orthogonally to the sagittal plane. A total number of three step cycles for each running condition were recorded (250 Hz). For each side of the body, 19 sagittal kinematic parameters from the lower extremity were evaluated. Results: Intraclass correlation coefficients (ICC) for both legs were high (generally > 0.80). Only the angular velocity parameters demonstrated correlation values below 0.70. The symmetry index for the linear and angular displacement parameters and the contact times during all running techniques were less than 8%, whereas those for the angular velocity parameters and flight times were higher than 15%. Conclusion: The present results suggested that the degree of reproducibility and symmetry of kinematic data do not vary with a deliberate change in running technique but rather depend on the parameter itself. With respect to the economy of data analysis, the present findings indicate that recording a single monolateral trial would provide reproducible and symmetric values for most kinematic parameters.
引用
收藏
页码:1009 / 1016
页数:8
相关论文
共 28 条
[1]   Mechanical power in running:: a comparison of different approaches [J].
Arampatzis, A ;
Knicker, A ;
Metzler, V ;
Brüggemann, GP .
JOURNAL OF BIOMECHANICS, 2000, 33 (04) :457-463
[2]   Test-retest reliability of selected ground reaction force parameters and their symmetry during running [J].
Bennell, K ;
Crossley, K ;
Wrigley, T ;
Nitschke, A .
JOURNAL OF APPLIED BIOMECHANICS, 1999, 15 (03) :330-336
[3]  
Cavanagh P.R., 1985, J APPL BIOMECH, V1, P36, DOI DOI 10.1123/IJSB.1.1.36
[4]  
CAVANAGH PR, 1990, BIOMECHANICS DISTANC, P65
[5]   Energy absorption of impacts during running at various stride lengths [J].
Derrick, TR ;
Hamill, J ;
Caldwell, GE .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (01) :128-135
[6]   Modeling the stiffness characteristics of the human body while running with various stride lengths [J].
Derrick, TR ;
Caldwell, GE ;
Hamill, J .
JOURNAL OF APPLIED BIOMECHANICS, 2000, 16 (01) :36-51
[7]   INTRADAY RELIABILITY OF GROUND REACTION FORCE DATA [J].
DEVITA, P ;
BATES, BT .
HUMAN MOVEMENT SCIENCE, 1988, 7 (01) :73-85
[8]   The reliability of kinetic and kinematic variables used to analyse normal running gait [J].
Diss, CE .
GAIT & POSTURE, 2001, 14 (02) :98-103
[9]   Leg stiffness and stride frequency in human running [J].
Farley, CT ;
Gonzalez, O .
JOURNAL OF BIOMECHANICS, 1996, 29 (02) :181-186
[10]  
FARLEY CT, 1993, J EXP BIOL, V185, P71