The measurement of impedance to assess myocardial contractility and rhythm stability

被引:5
作者
Arthur, W
Edgar, D
Kaye, GC
机构
[1] Castle Hill Hosp, Cottingham, E Yorks, England
[2] Biotron UK Ltd, Weston On The Green, Oxon, England
关键词
intracardiac impedance; conductance; contractility; rate modulation;
D O I
10.1088/0967-3334/21/4/201
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
By introducing an alternating current through the ventricular cavity via a multipolar catheter the potential difference measured between adjacent electrodes can be used to assess ventricular volume. This is possible by the measurement of intracardiac impedance. The data obtained can be used to construct pressure-volume loops allowing the continuous real-time assessment of myocardial contractility. Clinical applications of this research tool are now becoming apparent. Further derivations of impedance measurement have been incorporated into commercially available permanent pacing systems. allowing effective heart rate modulation.
引用
收藏
页码:R43 / R54
页数:12
相关论文
共 45 条
[1]
FEASIBILITY OF USING INTRACARDIAC IMPEDANCE MEASUREMENTS FOR CAPTURE DETECTION [J].
ALT, E ;
KRIEGLER, C ;
FOTUHI, P ;
WILLHAUS, R ;
COMBS, W ;
HEINZ, M ;
HAYES, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1873-1879
[2]
CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER [J].
BAAN, J ;
VANDERVELDE, ET ;
DEBRUIN, HG ;
SMEENK, GJ ;
KOOPS, J ;
VANDIJK, AD ;
TEMMERMAN, D ;
SENDEN, J ;
BUIS, B .
CIRCULATION, 1984, 70 (05) :812-823
[3]
BAAN J, 1982, CIRCULATION, V66, P277
[4]
CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER [J].
BAAN, J ;
JONG, TTA ;
KERKHOF, PLM ;
MOENE, RJ ;
VANDIJK, AD ;
VANDERVELDE, ET ;
KOOPS, J .
CARDIOVASCULAR RESEARCH, 1981, 15 (06) :328-334
[5]
Validation of a new intraoperative technique to evaluate load-independent indices of right ventricular performance in patients undergoing cardiac operations [J].
Brookes, CIO ;
White, PA ;
Bishop, AJ ;
Oldershaw, PJ ;
Redington, AN ;
Noat, NE .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (03) :468-476
[6]
Cabrera Fischer E I, 1988, Cardiovasc Res, V22, P185
[7]
Increased airway pressure and simulated branch pulmonary artery stenosis increase pulmonary regurgitation after repair of tetralogy of fallot - Real-time analysis with a conductance catheter technique [J].
Chaturvedi, RR ;
Kilner, PJ ;
White, PA ;
Bishop, A ;
Szwarc, R ;
Redington, AN .
CIRCULATION, 1997, 95 (03) :643-649
[8]
FEASIBILITY OF MEASURING RELATIVE RIGHT-VENTRICULAR VOLUMES AND EJECTION FRACTION WITH IMPLANTABLE RHYTHM CONTROL DEVICES [J].
CHIRIFE, R ;
ORTEGA, DF ;
SALAZAR, AI .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (08) :1673-1683
[9]
DICKSTEIN ML, 1995, CARDIOVASC RES, V29, P820, DOI 10.1016/0008-6363(96)88618-4
[10]
DiGregorio F, 1996, PACE, V19, P1689