High incidence of pathogenic microorganisms in bone allografts explanted in the morgue

被引:25
作者
Bettin, D
Harms, C
Polster, J
Niemeyer, T
机构
[1] Westfalische Wilhelms Universitat, Dept Orthoped, DE-48149 Munster, Germany
[2] Westfalische Wilhelms Universitat, Dept Microbiol, DE-48149 Munster, Germany
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1998年 / 69卷 / 03期
关键词
D O I
10.3109/17453679809000937
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We analyzed the influence of the environment on bacterial contamination in 431 bone allografts from 97 donors (68 multiorgan, grafts taken in the operation theater; 29 morgue donors). From each bone transplant we cultured two aerobic and two anaerobic tissue specimens, The overall contamination rate was 49% (theater 51%, morgue 40%). In grafts explanted in the morgue. we noted more pathogenic microorganisms (60%) than in multiorgan donors, explanted under aseptic surgical conditions (33%). We conclude that the harvesting environment constitutes the major source of pathogenic microorganisms.
引用
收藏
页码:311 / 314
页数:4
相关论文
共 19 条
[1]  
*AATB, 1979, GUID BANK MUSC TISS
[2]  
CARLSON CL, 1986, ADV CLIN CHILD PSYCH, V9, P153
[3]   Contamination of bone allografts - Analysis of incidence and predisposing factors [J].
Deijkers, RLM ;
Bloem, RM ;
Petit, PLC ;
Brand, R ;
Vehmeyer, SBW ;
Veen, MR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (01) :161-166
[4]  
DELLOYE C, 1989, BONE TRANSPLANTATION
[5]  
DOLAN CT, 1970, ARCH PATHOL, V92, P206
[6]  
EAMST EATB, 1997, COMM STAND MUSC TISS
[7]  
EASTLUND T, 1996, ORTHOPAEDIC ALLOGRAF
[8]  
MAKLEY JT, 1985, CLIN ORTHOP RELAT R, P58
[9]  
MALININ TI, 1985, CLIN ORTHOP RELAT R, P44
[10]  
MANKIN HJ, 1987, ORTHOP CLIN N AM, V18, P275