Fixation of bimaxillary osteotomies with resorbable plates and screws: Experience in 20 consecutive cases

被引:56
作者
Edwards, RC
Kiely, KD
Eppley, BL
机构
[1] Indiana Univ, Sch Med, Div Plast Surg, Indianapolis, IN 46202 USA
[2] Oral & Maxillofacial Surg Associates, Rochester, NY USA
[3] Univ Rochester, Sch Med, Rochester, NY USA
关键词
D O I
10.1053/joms.2001.20988
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated the potential effectiveness of resorbable plate and screw fixation for skeletal stabilization of simultaneously performed maxillary and mandibular osteotomies. Patients and Methods: Twenty consecutive patients underwent simultaneous maxillary and mandibular osteotomies that were fixed using copolymeric poly L-lactic acid/polyglycolic acid (PLLA/PGA) plates and screws. Prefabricated acrylic intermediate and final splints were used as guides and then removed at completion of the surgery. Guidance elastics were applied at 2 weeks postoperatively. Results: The LeFort I osteotomies included segmentalizations with and without bone grafts (7/20), impactions (4/20), advancements (8/20), and unilateral downgrafting with a bone graft (2/20)-one of which was segmental. The mandibular sagittal split osteotomies involved advancements (11/20), setbacks (5/20), and asymmetric rotation (4/20). Three patients had simultaneous genioplasties, which were also stabilized with resorbable fixation. All maxillae were fixed with four 2.0-mm L-shaped plates and screws, The mandibular rami were maintained with three 2.5-mm bicortical screws per side. The mandibular symphyseal segments were held in position with two or three 2.5 mm bicortical screws. All surgeries were accomplished uneventfully, and no problems in the immediate postoperative stability of the occlusion were encountered. Follow-up ranged from 12 to 25 months. Conclusions: The initial clinical findings suggest that this form of bone fixation is a viable alternative to standard metallic fixation techniques for certain maxillomandibular deformities in which excessive bony movements are not performed. Differences exist in both intraoperative application and postoperative management of masticatory function.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 26 条
[1]  
BELL WH, 1981, J ORAL SURG, V39, P666
[2]  
CONNOLE PW, 1971, J ORAL SURG, V29, P572
[3]   Resorbable fixation of Le fort I osteotomies [J].
Edwards, RC ;
Kiely, KD .
JOURNAL OF CRANIOFACIAL SURGERY, 1998, 9 (03) :210-214
[4]   Resorbable fixation techniques for genioplasty [J].
Edwards, RC ;
Kiely, KD ;
Eppley, BL .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 58 (03) :269-272
[5]   Resorbable PLLA-PGA screw fixation of mandibular sagittal split osteotomies [J].
Edwards, RC ;
Kiely, KD ;
Eppley, BL .
JOURNAL OF CRANIOFACIAL SURGERY, 1999, 10 (03) :230-236
[6]  
ELLIS E, 1996, SELECTED READINGS OR, V6, P1
[7]  
EPKER BN, 1975, J ORAL SURG, V33, P491
[8]   Use of a resorbable fixation technique for maxillary fractures [J].
Eppley, BL .
JOURNAL OF CRANIOFACIAL SURGERY, 1998, 9 (04) :317-321
[9]   Nonmetallic fixation in traumatic midfacial fractures [J].
Eppley, BL ;
Prevel, CD .
JOURNAL OF CRANIOFACIAL SURGERY, 1997, 8 (02) :103-109
[10]   Resorbable plate fixation in pediatric craniofacial surgery [J].
Eppley, BL ;
Sadove, AM ;
Havlik, RJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 100 (01) :1-7