Super-cooled water behavior inside polymer electrolyte fuel cell cross-section below freezing temperature

被引:141
作者
Ishikawa, Y. [1 ]
Hamada, H. [2 ]
Uehara, M. [3 ]
Shiozawa, M. [1 ]
机构
[1] NIPPON SOKEN INC, 14 Iwaya,Shimohasumi-cho, Nishio City, Aichi 4450012, Japan
[2] Toyota Motor Co Ltd, Toyota, Aichi 4718572, Japan
[3] DENSO, Kariya, Aichi 4488661, Japan
关键词
PEM; fuel cell; cold start; freezing point; ice; super-cooled water;
D O I
10.1016/j.jpowsour.2008.01.031
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 [物理化学]; 081704 [应用化学];
摘要
This study investigated the phenomenon of water freezing below freezing point in polymer electrolyte fuel cells (PEFCs). To understand the details of water freezing phenomena inside a PEFC, a system capable of cross-sectional imaging inside the fuel cell with visible and infrared images was developed. Super-cooled water freezing phenomena were observed under different gas purge conditions. The present test confirmed that super-cooled water was generated on the gas diffusion layer (GDL) surface and that water freezing occurs at the interface between the GDL and MEA (membrane electrode assembly) at the moment cell performance deteriorates under conditions when remaining water was dry enough inside the fuel cell before cold starting. Moreover, using infrared radiation imaging, it was clarified that heat of solidification spreads at the GDL/MEA interface at the moment cell performance drops. Compared with a no-initial purge condition, liquid water generation was not confirmed to cause ice growth at the GDL/MEA interface after cell performance deterioration. Each condition indicated that ice formation at the GDL/MEA interface causes cell performance deterioration. Therefore, it is believed that ice formation between the GDL/MEA interface causes air gas stoppage and that this blockage leads to a drop in cell performance. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:547 / 552
页数:6
相关论文
共 13 条
[1]
In situ Imaging of liquid water and ice formation in an operating PEFC during cold start [J].
Ge, Shanhai ;
Wang, Chao-Yang .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2006, 9 (11) :A499-A503
[2]
Geiger AB, 2003, FUEL CELLS, V2, P92
[3]
Behavior of water below the freezing point in PEFCs [J].
Ishikawa, Y. ;
Morita, T. ;
Nakata, K. ;
Yoshida, K. ;
Shiozawa, M. .
JOURNAL OF POWER SOURCES, 2007, 163 (02) :708-712
[4]
In situ diagnostic of two-phase flow phenomena in polymer electrolyte fuel cells by neutron imaging Part A. Experimental, data treatment, and quantification [J].
Kramer, D ;
Zhang, JB ;
Shimoi, R ;
Lehmann, E ;
Wokaun, A ;
Shinohara, K ;
Scherer, GG .
ELECTROCHIMICA ACTA, 2005, 50 (13) :2603-2614
[5]
NAKAMIYA H, 2005, JPN SOC MECH ENG, V5, P1
[6]
NANJYO M, 1963, ENCY CHIM, P842
[7]
OGAWA T, 2004, THERMAL SCI ENG, V12, P4
[8]
PERBEN JSV, 2004, ELECTROCHIM ACTA, V1069, P49
[9]
SAITO M, 2004, 45 BATT S JAP, P692
[10]
In situ neutron imaging technique for evaluation of water management systems in operating PEM fuel cells [J].
Satija, R ;
Jacobson, DL ;
Arif, M ;
Werner, SA .
JOURNAL OF POWER SOURCES, 2004, 129 (02) :238-245