A theoretical analysis of the response of a simple straight tube meter, a finite element simulation of the step response of complex geometry flow tubes, and an extensive experimental study were performed. Experiments were carried out on eight currently available Coriolis meters, provided by five different manufacturers. Meter sizes ranged from 15 mm to 50 mm with six different flow tube geometries. The resultant data were analyzed in detail.