Coriolis flow meters - the potential for outstanding dynamic performance

被引:3
作者
Clark, C [1 ]
Cheesewright, R [1 ]
机构
[1] Brunel Univ, Dept Design & Syst Engn, Uxbridge UB8 3PH, Middx, England
关键词
D O I
10.1177/002029400303600903
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A theoretical analysis of the response of a simple straight tube meter, a finite element simulation of the step response of complex geometry flow tubes, and an extensive experimental study were performed. Experiments were carried out on eight currently available Coriolis meters, provided by five different manufacturers. Meter sizes ranged from 15 mm to 50 mm with six different flow tube geometries. The resultant data were analyzed in detail.
引用
收藏
页码:275 / +
页数:4
相关论文
共 3 条
  • [1] CHEESEWRIGHT R, 2003, IN PRESS J FLUIDS ST
  • [2] CHEESEWRIGHT R, 2000, FLUCOME 2000
  • [3] WIKLUND D, 2002, ISA 2002 TECHN C CHI