Analysis and Design of Resonant Current Controllers for Voltage-Source Converters by Means of Nyquist Diagrams and Sensitivity Function

被引:322
作者
Yepes, Alejandro G. [1 ]
Freijedo, Francisco D. [1 ]
Lopez, Oscar [1 ]
Doval-Gandoy, Jesus [1 ]
机构
[1] Univ Vigo, Dept Elect Technol, Vigo 36310, Spain
关键词
Current control; power conditioning; pulsewidth-modulated (PWM) power converters; resonant controllers; SELECTIVE HARMONIC-COMPENSATION; PREDICTIVE CURRENT CONTROL; ACTIVE POWER FILTERS; STEADY-STATE-ERROR; LOOP CONTROL; PERFORMANCE; FREQUENCY; PHASE; INVERTERS; INTEGRATORS;
D O I
10.1109/TIE.2011.2126535
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The following two types of resonant controllers are mainly employed to obtain high performance in voltage-source converters: 1) proportional + resonant (PR) and 2) vector proportional + integral (VPI). The analysis and design of PR controllers is usually performed by Bode diagrams and phase-margin criterion. However, this approach presents some limitations when resonant frequencies are higher than the crossover frequency defined by the proportional gain. This condition occurs in selective harmonic control and applications with high reference frequency with respect to the switching frequency, e.g., high-power converters with a low switching frequency. In such cases, additional 0-dB crossings (phase margins) appear; therefore, the usual methods for simple systems are no longer valid. In addition, VPI controllers always present multiple 0-dB crossings in their frequency response. In this paper, the proximity to the instability of PR and VPI controllers is evaluated and optimized through Nyquist diagrams. A systematic method is proposed to obtain the highest stability and avoidance of closed-loop anomalous peaks: it is achieved by the minimization of the inverse of the Nyquist trajectory distance to the critical point, i.e., the sensitivity function. Finally, several experimental tests, including an active power filter that operates at a low switching frequency and compensates harmonics up to the Nyquist frequency, validate the theoretical approach.
引用
收藏
页码:5231 / 5250
页数:20
相关论文
共 53 条
  • [1] Three-Level NPC Converter-Based Predictive Direct Power Control of the Doubly Fed Induction Machine at Low Constant Switching Frequency
    Abad, Gonzalo
    Rodriguez, Miguel Angel
    Poza, Javier
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) : 4417 - 4429
  • [2] Medium-Voltage Multilevel Converters-State of the Art, Challenges, and Requirements in Industrial Applications
    Abu-Rub, Haitham
    Holtz, Joachim
    Rodriguez, Jose
    Ge Baoming
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (08) : 2581 - 2596
  • [3] Akagi H, 2007, INSTANTANEOUS POWER
  • [4] [Anonymous], P 35 ANN IEEE IECON
  • [5] [Anonymous], 2009, MODERN CONTROL ENG
  • [6] Harmonic filtering of high-power 12-pulse rectifier loads with a selective hybrid filter system
    Basic, D
    Ramsden, VS
    Muttik, PK
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2001, 48 (06) : 1118 - 1127
  • [7] Active Damping for Three-Phase PWM Rectifiers With High-Order Line-Side Filters
    Bierhoff, Michael H.
    Fuchs, Friedrich Wilhelm
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (02) : 371 - 379
  • [8] Bojoi R., 2008, IECON 2008 - 34th Annual Conference of IEEE Industrial Electronics Society, P3141, DOI 10.1109/IECON.2008.4758463
  • [9] Analysis of Current Controllers for Active Power Filters Using Selective Harmonic Compensation Schemes
    Bojoi, Radu
    Limongi, Leonardo R.
    Profumo, Francesco
    Roiu, Daniel
    Tenconi, Alberto
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2009, 4 (02) : 139 - 157
  • [10] Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame
    Bojoi, RI
    Griva, G
    Bostan, V
    Guerriero, M
    Farina, F
    Profumo, F
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) : 1402 - 1412