Extravascular lung water and intrathoracic blood volume: double versus single indicator dilution technique

被引:90
作者
Neumann, P [1 ]
机构
[1] Univ Uppsala, Dept Clin Physiol, S-75185 Uppsala, Sweden
关键词
extravascular lung water; intrathoracic blood volume; thermodilution; thermo-dye dilution;
D O I
10.1007/s001340050819
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The accuracy of single thermodilution was assessed in measuring extravascular lung water (EVLW) and intrathoracic blood volume (ITBV). Design: Single thermodilution ((ST)) was prospectively compared with thermo-dye dilution ((TD)) in 13 mechanically ventilated pigs using the Pulsion Cold Z-021 monitor. Interventions: Lung injury was induced with oleic acid injection. Results: EVLWITD increased from 4.3 +/- 1.4 to 11.3 +/- 4.5 ml/kg (p = 0.0014) and ITBVTD decreased from 581 +/- 66 to 540 +/- 85 mi (p = 0.039) after induction of lung injury. EVLWST was systematically overestimated (0.5-1 ml/kg) and ITBVST was slightly underestimated (15-20 ml) when calculated automatically by the Pulsion Cold Z-021 monitor. This bias could be removed by adjusting two coefficients needed for the computation of ITBVST and EVLWST so that the following regression equations were obtained: EVLWIST = 0.98 . EVLWITD + 0.27 (r = 0.94, p < 10(-6)) and ITBVST = 1.0.ITBVTD + 0 (r = 0.87, p < 10(-6)). Conclusions: Single thermodilution allows estimation of ITBV and EVLW values with reasonable accuracy and therefore provides useful information about the cardiac preload and the severity of lung injury. However, automatic calculation of EVLWIST and ITBVST using the Pulsion Cold Z-021 might be biased. Therefore, researchers and clinicians should validate single thermodilution for the given settings, before employing this method to estimate EVLW and ITBV.
引用
收藏
页码:216 / 219
页数:4
相关论文
共 8 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Assessment of intrathoracic blood volume. Thermo-dye dilution technique vs single-thermodilution technique [J].
Buhre, W ;
Bendyk, K ;
Weyland, A ;
Kazmaier, S ;
Schmidt, M ;
Mursch, K ;
Sonntag, H .
ANAESTHESIST, 1998, 47 (01) :51-53
[3]   A PROSPECTIVE-STUDY OF LUNG WATER MEASUREMENTS DURING PATIENT-MANAGEMENT IN AN INTENSIVE-CARE UNIT [J].
EISENBERG, PR ;
HANSBROUGH, JR ;
ANDERSON, D ;
SCHUSTER, DP .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (03) :662-668
[4]   INTRATHORACIC BLOOD-VOLUME ACCURATELY REFLECTS CIRCULATORY VOLUME STATUS IN CRITICALLY ILL PATIENTS WITH MECHANICAL VENTILATION [J].
LICHTWARCKASCHOFF, M ;
ZERAVIK, J ;
PFEIFFER, UJ .
INTENSIVE CARE MEDICINE, 1992, 18 (03) :142-147
[5]   ON THE THEORY OF THE INDICATOR-DILUTION METHOD FOR MEASUREMENT OF BLOOD FLOW AND VOLUME [J].
MEIER, P ;
ZIERLER, KL .
JOURNAL OF APPLIED PHYSIOLOGY, 1954, 6 (12) :731-744
[6]  
NEWMAN EV, 1951, CIRCULATION, V4, P735, DOI 10.1161/01.CIR.4.5.735
[7]  
*PULS MED SYST, 1995, US MAN PULS COLD Z 0
[8]   Quantitative estimation of errors in the indicator dilution measurement of extravascular lung water [J].
Wallin, CJB ;
Rosblad, PG ;
Leksell, LG .
INTENSIVE CARE MEDICINE, 1997, 23 (04) :469-475