Bioanalytical applications of polyion-sensitive electrodes

被引:25
作者
Dai, S
Esson, JM
Lutze, O
Ramamurthy, N
Yang, VC
Meyerhoff, ME [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Coll Pharm, Ann Arbor, MI 48109 USA
关键词
polyion-sensitive electrode; protease assays; non-separation immunoassay; heparin determination;
D O I
10.1016/S0731-7085(98)00134-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent developments in the design and bioanalytical applications of polyion-sensitive electrodes (PSEs) are reviewed. The general electrochemical principles governing the potentiometric response of such polymer membrane-based devices are summarized and new directions for the use of these novel sensors are detailed. These new directions include basic fundamental studies aimed at determining the thermodynamics of polyion extraction into ion exchanger-doped polymeric membranes, new methods to quantitate the anticoagulant drug heparin in whole blood via titrations with polycationic protamine, selective assays of protease activities land inhibitors of such activities) using natural and synthetic polyionic peptides as substrates, and novel homogeneous immunoassay schemes based on potentiometric polyion detection. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 26 条
[1]   Electrochemical assay of proteinase inhibitors using polycation-sensitive membrane electrode detection [J].
Badr, IHA ;
Ramamurthy, N ;
Yang, VC ;
Meyerhoff, ME .
ANALYTICAL BIOCHEMISTRY, 1997, 250 (01) :74-81
[2]  
Cohen EJ., 1980, J Extra Corpor Technol, V12, P139, DOI [10.1051/ject/1980126139, DOI 10.1051/JECT/1980126139]
[3]   Polyion-sensitive membrane electrodes for detecting phosphate-rich biological polyanions [J].
Esson, JM ;
Meyerhoff, ME .
ELECTROANALYSIS, 1997, 9 (17) :1325-1330
[4]   POLYMER MEMBRANE-BASED POLYION SENSORS - DEVELOPMENT, RESPONSE MECHANISM, AND BIOANALYTICAL APPLICATIONS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
WANG, EJ ;
YANG, VC ;
MEYERHOFF, ME .
ELECTROANALYSIS, 1995, 7 (09) :823-829
[5]   EXTRACTION THERMODYNAMICS OF POLYANIONS INTO PLASTICIZED POLYMER MEMBRANES DOPED WITH LIPOPHILIC ION-EXCHANGERS - A POTENTIOMETRIC STUDY [J].
FU, B ;
BAKKER, E ;
YANG, VC ;
MEYERHOFF, ME .
MACROMOLECULES, 1995, 28 (17) :5834-5840
[6]   RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[7]   Selective monitoring of peptidase activities with synthetic polypeptide substrates and polyion-sensitive membrane electrode detection [J].
Han, IS ;
Ramamurthy, N ;
Yun, JH ;
Schaller, U ;
Meyerhoff, ME ;
Yang, VC .
FASEB JOURNAL, 1996, 10 (14) :1621-1626
[8]   FLOW-THROUGH ION SENSOR FOR SENSING OF ANIONIC POLYELECTROLYTE USING A PLASTICIZED POLY(VINYL CHLORIDE) MEMBRANE DOPED WITH TETRADECYLDIMETHYLBENZYLAMMONIUM CHLORIDE [J].
HATTORI, T ;
KATO, M .
ANALYTICAL SCIENCES, 1995, 11 (02) :285-287
[9]  
HIRSH J, 1984, NOUV REV FR HEMATOL, V26, P261
[10]  
JAQUES LB, 1979, PHARMACOL REV, V31, P99