Auditory evoked potential index predicts the depth of sedation and movement in response to skin incision during sevoflurane anesthesia

被引:84
作者
Kurita, T [1 ]
Doi, M [1 ]
Katoh, T [1 ]
Sano, H [1 ]
Sato, S [1 ]
Mantzaridis, H [1 ]
Kenny, GNC [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Anesthesiol & Intens Care, Hamamatsu, Shizuoka 4313192, Japan
关键词
D O I
10.1097/00000542-200108000-00017
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The auditory evoked potential (AEP) index, which is a single numerical parameter derived from the AEP in real time and which describes the underlying morphology of the AEP, has been studied as a monitor of anesthetic depth. The current study was designed to evaluate the accuracy of AEPindex for predicting depth of sedation and anesthesia during sevoflurane anesthesia. Methods. In the first phase of the study, a single end-tidal sevoflurane concentration ranging from 0.5 to 0.9% was assigned randomly and administered to each of 50 patients. The AEPindex and the Bispectral Index (BIS) were obtained simultaneously. Sedation was assessed using the responsiveness portion of the observer's assessment of alertness-sedation scale. in the second phase of the study, 10 additional patients were included, and the 60 patients who were scheduled to have skin incisions were observed for movement in response to skin incision at the end-tidal sevoflurane concentrations between 1.6 and 2.6%. The relation among AEPindex, BIS, sevoflurane concentration, sedation score, and movement or absence of movement after skin incision was determined. Prediction probability values for AEPindex, BIS, and sevoflurane concentration to predict depth of sedation and anesthesia were also calculated. Results: The AEPindex, BIS, and sevoflurane concentration correlated closely with the sedation score. The prediction probability values for AEPindex, BIS, and sevoflurane concentration for sedation score were 0.820, 0.805, and 0.870,respectively, indicating a high predictive performance for depth of sedation. AEPindex and sevoflurane concentration successfully predicted movement after skin (prediction probability = 0.910 and 0.857, respectively), whereas BIS could not (prediction probability = 0.537). Conclusions. Auditory evoked potential index can be a guide to the depth of sedation and movement in response to skin incision during sevoflurane anesthesia.
引用
收藏
页码:364 / 370
页数:7
相关论文
共 22 条
[1]  
CHERNIK DA, 1990, J CLIN PSYCHOPHARM, V10, P244
[2]   Middle latency auditory evoked potentials during repeated transitions from consciousness to unconsciousness [J].
Davies, FW ;
Mantzaridis, H ;
Kenny, GNC ;
Fisher, AC .
ANAESTHESIA, 1996, 51 (02) :107-113
[3]   Prediction of movement at laryngeal mask airway insertion: comparison of auditory evoked potential index, bispectral index, spectral edge frequency and median frequency [J].
Doi, M ;
Gajraj, RJ ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (02) :203-207
[4]   Relationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: Comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index [J].
Doi, M ;
Gajraj, RJ ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 78 (02) :180-184
[5]   Forty-hertz midlatency auditory evoked potential activity predicts wakeful response during desflurane and propofol anesthesia in volunteers [J].
Dutton, RC ;
Smith, WD ;
Rampil, IJ ;
Chortkoff, BS ;
Eger, EI .
ANESTHESIOLOGY, 1999, 91 (05) :1209-1220
[6]   Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness [J].
Gajraj, RJ ;
Doi, M ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (01) :46-52
[7]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[8]   Electroencephalographic derivatives as a tool for predicting the depth of sedation and anesthesia induced by sevoflurane [J].
Katoh, T ;
Suzuki, A ;
Ikeda, K .
ANESTHESIOLOGY, 1998, 88 (03) :642-650
[9]   THE MINIMUM ALVEOLAR CONCENTRATION (MAC) OF SEVOFLURANE IN HUMANS [J].
KATOH, T ;
IKEDA, K .
ANESTHESIOLOGY, 1987, 66 (03) :301-303
[10]   BISPECTRAL ANALYSIS OF THE ELECTROENCEPHALOGRAM CORRELATES WITH PATIENT MOVEMENT TO SKIN INCISION DURING PROPOFOL NITROUS-OXIDE ANESTHESIA [J].
KEARSE, LA ;
MANBERG, P ;
CHAMOUN, N ;
DEBROS, F ;
ZASLAVSKY, A .
ANESTHESIOLOGY, 1994, 81 (06) :1365-1370