A rapid and sensitive method for methyl tert-butyl ether analysis in water samples by use of solid phase microextraction and gas chromatography-mass spectrometry

被引:41
作者
Piazza, F
Barbieri, A
Violante, FS
Roda, A
机构
[1] Univ Bologna, Dipartimento Sci Farmaceut, I-40126 Bologna, Italy
[2] St Orsola Marcello Malpighi Hosp, Safety Hyg & Occupat Med Serv, Bologna, Italy
[3] St Orsola Marcello Malpighi Hosp, Occupat Hlth Serv, Bologna, Italy
关键词
MTBE; solid phase microextraction; GC-MS; water;
D O I
10.1016/S0045-6535(00)00501-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work describes a rapid and sensitive solid-phase microextraction (SPME) method for the isolation and analysis of methyl tert-butyl ether in water samples. Methyl tert-butyl ether was extracted from aqueous solutions using SPME fibre coated with Divinylbenzene/Carboxen (TM) /polydimethylsiloxane (30 mum film thickness) and analysed by GC-MS with a Hewlett Packard 6890/5973 system equipped with a capillary column coated with Vocol (TM) (30 m x 0.25 mm, 1.5 mum film thickness). Extraction parameters and chromatographic separation conditions were optimised. The developed method showed good analytical performance in terms of precision (RSD between 2% and 8%) and accuracy (mean recovery from 96% to 104%) with a detection limit of 14 ppt. Finally the method was applied to surface, tap and commercial mineral water samples, as well as snow samples collected along a busy road of Bologna town area. The median concentration of methyl tert-butyl ether in all these samples (0.05-0.4 ppb) was well below the maximum aqueous contamination levels in water adopted in the United States (13 ppb). (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:539 / 544
页数:6
相关论文
共 20 条
[1]  
ACTHEN CA, 2000, ENVIRON SCI TECHNOL, V34, P1359
[2]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[3]   DETERMINATION OF VOLATILE CHLORINATED HYDROCARBONS IN AIR AND WATER WITH SOLID-PHASE MICROEXTRACTION [J].
CHAI, M ;
ARTHUR, CL ;
PAWLISZYN, J ;
BELARDI, RP ;
PRATT, KF .
ANALYST, 1993, 118 (12) :1501-1505
[4]  
DELZER GC, 1996, 964145 US GEOGR SURV
[5]  
Gaines RB, 1998, J MICROCOLUMN SEP, V10, P597
[6]   SAMPLE INTRODUCTION APPROACHES FOR SOLID-PHASE MICROEXTRACTION RAPID GC [J].
GORECKI, T ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3265-3274
[7]   Analysis of methyl tert.-butyl ether and its degradation products by direct aqueous injection onto gas chromatography with mass spectrometry or flame ionization detection systems [J].
Hong, S ;
Duttweiler, CM ;
Lemley, AT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :205-216
[8]  
KOTERBA MT, 1995, 9533 US GEOL SURV
[9]  
LopezAvila V, 1997, HRC-J HIGH RES CHROM, V20, P487, DOI 10.1002/jhrc.1240200905
[10]   DYNAMICS OF ORGANIC-COMPOUND EXTRACTION FROM WATER USING LIQUID-COATED FUSED-SILICA FIBERS [J].
LOUCH, D ;
MOTLAGH, S ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1187-1199