Summarizing the effectiveness of supercritical fluid extraction of polycyclic aromatic hydrocarbons from natural matrix environmental samples

被引:53
作者
Benner, BA [1 ]
机构
[1] NIST, Chem Sci & Technol Lab, Div Analyt Chem, Gaithersburg, MD 20899 USA
关键词
D O I
10.1021/ac980618f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A summary of the supercritical fluid extraction (SFE) of polycyclic aromatic hydrocarbons (PAHs) from four natural matrix Standard Reference Materials (SRMs) is presented. The work involved the investigation of the effects of extraction fluid [carbon dioxide (CO2), chlorodifluoromethane (R22), and 1,1, 1,2-tetrafluoroethane (HFC134a)], fluid modifier (dichloromethane and aniline), temperature (60, 150, and 200 degrees C) and added water on the SFE recoveries of PAHs compared to certified results from Soxhlet extractions. For SRM 1649a (Urban Dust/Organics), R22 yielded excellent recoveries (>90% of certified concentrations) of all PAHs measured, while results for the same SRM using HFC134a as the fluid were typically <80% of the certified concentrations for most of the PAHs measured. For SRM 1941a and 1944, both aquatic sediments with similar physical and chemical compositions, extractions of the wet materials with dichloromethane-modified CO2 (10%, v/v) yielded quantitative recoveries of all PAHs for SRM 1944 but an obvious trend of lower recoveries for higher molecular weight PAHs (greater than or equal to 228 amu) for SRM 1941a, Results of SFEs of SRM 1650 (Diesel Particulate Matter) showed that this material is the most refractory of the SRMs investigated in this study, with recoveries of indeno[1,2,3-cd]pyrene and benzo[ghi]perylene at <20% of the Soxhlet results.
引用
收藏
页码:4594 / 4601
页数:8
相关论文
共 21 条
[1]  
*AIR COND HEAT PUM, 1991, MONTR PROT 1994 ASS
[2]   EXTRACTION RATES OF SPIKED VERSUS NATIVE PAHS FROM HETEROGENEOUS ENVIRONMENTAL-SAMPLES USING SUPERCRITICAL-FLUID EXTRACTION AND SONICATION IN METHYLENE-CHLORIDE [J].
BURFORD, MD ;
HAWTHORNE, SB ;
MILLER, DJ .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1497-1505
[3]   QUANTITATIVE-ANALYSIS USING DIRECTLY COUPLED SUPERCRITICAL FLUID EXTRACTION CAPILLARY GAS-CHROMATOGRAPHY (SFE-GC) WITH A CONVENTIONAL SPLIT SPLITLESS INJECTION PORT [J].
HAWTHORNE, SB ;
MILLER, DJ ;
LANGENFELD, JJ .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (01) :2-8
[4]   DIRECTLY COUPLED SUPERCRITICAL FLUID EXTRACTION GAS-CHROMATOGRAPHIC ANALYSIS OF POLYCYCLIC AROMATIC-HYDROCARBONS AND POLYCHLORINATED-BIPHENYLS FROM ENVIRONMENTAL SOLIDS [J].
HAWTHORNE, SB ;
MILLER, DJ .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :63-76
[5]   COMPARISON OF SUPERCRITICAL CHCLF2, N2O, AND CO2 FOR THE EXTRACTION OF POLYCHLORINATED-BIPHENYLS AND POLYCYCLIC AROMATIC-HYDROCARBONS [J].
HAWTHORNE, SB ;
LANGENFELD, JJ ;
MILLER, DJ ;
BURFORD, MD .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1614-1622
[6]   EXTRACTION AND RECOVERY OF POLYCYCLIC AROMATIC-HYDROCARBONS FROM ENVIRONMENTAL SOLIDS USING SUPERCRITICAL FLUIDS [J].
HAWTHORNE, SB ;
MILLER, DJ .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1705-1708
[7]  
HAWTHORNE SB, 1995, COMMUNICATION
[8]   ROLE OF MODIFIERS FOR ANALYTICAL-SCALE SUPERCRITICAL-FLUID EXTRACTION OF ENVIRONMENTAL-SAMPLES [J].
LANGENFELD, JJ ;
HAWTHORNE, SB ;
MILLER, DJ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (06) :909-916
[9]   KINETIC-STUDY OF SUPERCRITICAL-FLUID EXTRACTION OF ORGANIC CONTAMINANTS FROM HETEROGENEOUS ENVIRONMENTAL-SAMPLES WITH CARBON-DIOXIDE AND ELEVATED-TEMPERATURES [J].
LANGENFELD, JJ ;
HAWTHORNE, SB ;
MILLER, DJ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1727-1736
[10]   EFFECTS OF TEMPERATURE AND PRESSURE ON SUPERCRITICAL FLUID EXTRACTION EFFICIENCIES OF POLYCYCLIC AROMATIC-HYDROCARBONS AND POLYCHLORINATED-BIPHENYLS [J].
LANGENFELD, JJ ;
HAWTHORNE, SB ;
MILLER, DJ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :338-344