Selective and sensitive fluorometric determinations of cobalt(II) and hydrogen peroxide with fluorescein-hydrazide

被引:70
作者
Mori, I [1 ]
Takasaki, K [1 ]
Fujita, Y [1 ]
Matsuo, T [1 ]
机构
[1] Osaka Univ Pharmaceut Sci, Osaka 5691094, Japan
关键词
cobalt(II); fluorescein-hydrazide; hydrogen peroxide;
D O I
10.1016/S0039-9140(98)00118-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fluorophotometric determinations of cobalt(II) and hydrogen peroxide were investigated by using the fluorescence reaction between fluorescein-hydrazide (fl-NHNH2), and/or hydrogen peroxide, cobalt(II), respectively. The calibration graphs were liner in the range of 0-6.0 ng cobalt(II) and 0-1000 ng hydrogen peroxide per 10 ml at an emission wavelength (E-m) of 530 nm with an exicitation wavelength (E-x) of 508 nm, respectively. These proposed methods were selective and simple, and the effect of foreign ions was negligible in comparison with conventional reported methods such as nitroso R,4-(2-pyridylazo)resorcinol(PAR), alizarin, pyridine-2-aldehyde-2-pyridinehydrazone, stilbazo-cobalt(II), etc. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:631 / 637
页数:7
相关论文
共 14 条
[1]  
AKITA T, 1961, YAKUGAKU ZASSHI, V81, P517
[2]   SPECTROPHOTOMETRIC DETERMINATION OF HYDROGEN-PEROXIDE USING O-HYDROXYHYDROQUINONEPHTHALEIN, TITANIUM(IV) AND ETHYLENEDIAMINETETRAACETIC ACID [J].
FUJITA, Y ;
MORI, I ;
TOYODA, M ;
MATSUO, T .
ANALYTICAL SCIENCES, 1994, 10 (05) :827-830
[3]  
LEBATESSTELLS E, 1986, ANALYST, V111, P193
[4]   STUDY OF THE FLUORESCENCE OF THE LEAD MORIN SYSTEM IN THE PRESENCE OF NONIONIC SURFACTANTS [J].
MEDINA, J ;
HERNANDEZ, F ;
MARIN, R ;
LOPEZ, FJ .
ANALYST, 1986, 111 (02) :235-237
[5]   THE APPLICATION OF DIARYLAMINE COMPOUNDS IN ANALYTICAL-CHEMISTRY .4. SIMPLE FLUOROPHOTOMETRIC DETERMINATION OF COBALT(II) WITH PARA-HYDROXY-2-ANILINOPYRIDINE AND HYDROGEN-PEROXIDE [J].
MORI, I ;
FUJITA, Y ;
TOYODA, M ;
HAMADA, M ;
AKAGI, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (12) :902-904
[6]   HIGHLY SENSITIVE SPECTROPHOTOMETRIC DETERMINATION OF COBALT USING ORTHO-HYDROXYHYDROQUINONEPHTHALEIN AND HYDROGEN-PEROXIDE IN THE PRESENCE OF MIXED SURFACTANTS [J].
MORI, I ;
FUJITA, Y ;
FUJITA, K ;
NAKAHASHI, Y ;
TANAKA, T ;
ISHIHARA, S .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 330 (07) :619-623
[7]   APPLICATION OF XANTHENE DERIVATIVES TO ANALYTICAL-CHEMISTRY .76. - SELECTIVE FLUORIMETRIC DETERMINATION OF TRACE AMOUNTS OF COBALT(II) WITH THE SYSTEM OF FLUORESCEIN HYDROGEN-PEROXIDE TIRON [J].
MORI, I ;
FUJITA, Y ;
NAKAHASHI, Y ;
IKUTA, K ;
KATO, K .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1989, 62 (08) :2536-2540
[8]   THE APPLICATION OF DAIRYLAMINE COMPOUNDS IN ANALYTICAL-CHEMISTRY .3. FLUOROMETRIC-DETERMINATION OF HYDROGEN-PEROXIDE BY USE OF THE FLUORESCENCE REACTION BETWEEN N-(4'-HYDROXYPHENYL)-N-(4-METHYLQUINOLINYL)AMINE AND COBALT(II) IN THE PRESENCE OF TRIMETHYLSTEARYLAMMONIUM CHLORIDE [J].
MORI, I ;
FUJITA, Y ;
TOYODA, M ;
KATO, K ;
YOSHIDA, N ;
AKAGI, M .
TALANTA, 1991, 38 (06) :683-686
[9]  
NANOV D, 1982, ANAL CHIM ACTA, V183, P321
[10]   INORGANIC DIFFERENTIAL KINETIC-ANALYSIS - A REVIEW [J].
PEREZBENDITO, D .
ANALYST, 1984, 109 (07) :891-899