Effects of limb-length discrepancy on gait economy and lower-extremity muscle activity in older adults

被引:172
作者
Gurney, B
Mermier, C
Robergs, R
Gibson, A
Rivero, D
机构
[1] Univ New Mexico, Div Phys Therapy, Albuquerque, NM 87131 USA
[2] Univ New Mexico, Div Phys Performance Dev, Johnson Ctr, Albuquerque, NM 87131 USA
[3] Univ New Mexico, Hlth Sci Ctr, Dept Orthopaed, Albuquerque, NM 87131 USA
关键词
D O I
10.2106/00004623-200106000-00013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The amount of limb-length discrepancy necessary to adversely affect gait parameters in older adults is unknown, with information being largely anecdotal. This investigation was conducted to determine the effects of limb-length discrepancy on gait economy and lower-extremity muscle activity in older adults. Methods: Forty-four men and women ranging in age from fifty-five to eighty-six years with no evidence of limb-length discrepancy of >1 cm participated in the study. Subjects walked on a treadmill at a self-selected normal walking pace with artificial limb-length discrepancies of 0, 2, 3, and 4 cm applied in a randomly selected order. Indirect calorimetry was used to measure oxygen consumption and minute ventilation. Electromyography was used to measure muscle activity of the right and left quadriceps femoris, plantar flexors, gluteus maximus, and gluteus medius. Heart rate, the rating of perceived exertion, and frequency of gait compensation patterns were also measured. Results: There was a significant increase in oxygen consumption and the rating of perceived exertion with 2, 3, and 4-cm artificial limb-length discrepancies; a significant increase in heart rate, minute ventilation, and quadriceps activity in the longer limb with 3 and 4-cm artificial limb-length discrepancies; and a significant increase in plantar flexor activity in the shorter limb with a 4-cm artificial limb-length discrepancy compared with the same parameters with no artificial limb-length discrepancy. Conclusions: Both oxygen consumption and the rating of perceived exertion were greater with a 2-cm artificial limb-length discrepancy than they were with no artificial limb-length discrepancy. There appears to be a breakpoint between 2 and 3 cm of artificial limb-length discrepancy in older adults with regard to the effects on most other physiological parameters. A 3-cm artificial limb-length discrepancy is likely to induce significant quadriceps fatigue in the longer limb. Elderly patients with substantial pulmonary, cardiac, or neuromuscular disease may have difficulty walking with a limb-length discrepancy as small as 2 cm.
引用
收藏
页码:907 / 915
页数:9
相关论文
共 49 条
[1]
ABRAHAM WD, 1992, ORTHOP CLIN N AM, V23, P201
[2]
BASSILLE CC, 1996, NEUROL REP, V20, P31
[3]
VALIDITY OF DERIVED MEASUREMENTS OF LEG-LENGTH DIFFERENCES OBTAINED BY USE OF A TAPE MEASURE [J].
BEATTIE, P ;
ISAACSON, K ;
RIDDLE, DL ;
ROTHSTEIN, JM .
PHYSICAL THERAPY, 1990, 70 (03) :150-157
[4]
Improvement in gait parameters after lengthening for the treatment of limb-length discrepancy [J].
Bhave, A ;
Paley, D ;
Herzenberg, JE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (04) :529-534
[5]
PSYCHOPHYSICAL BASES OF PERCEIVED EXERTION [J].
BORG, GAV .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (05) :377-381
[6]
Brand RA, 1996, CLIN ORTHOP RELAT R, P172
[7]
BRUNET ME, 1990, J SPORT MED PHYS FIT, V30, P307
[8]
CANDER L, 1964, AGING LUNG PERSPECTI, P132
[9]
CAULEY JA, 1994, S COND NAT I HLTH AN
[10]
Costello E, 1996, NEUROLOGY REPORT, V20, P24