Long-term histological and immunohistochemical findings in human venous aorto-coronary bypass grafts

被引:21
作者
Ribichin, Flavio [1 ]
Pugno, Francesco [2 ]
Ferrero, Valeria [1 ]
Wijns, William [3 ]
Vacca, Giovanni [4 ]
Vassanelli, Corrado [1 ]
Virmani, Renu [5 ]
机构
[1] Univ Verona, Dept Biomed Sci & Surg, Div Cardiol, I-37126 Verona, Italy
[2] Osped Cottolengo, Lab Human Pathol, I-10100 Turin, Italy
[3] Onze Lieve Vrouw Hosp, Cardiovasc Ctr Aalst, B-9300 Aalst, Belgium
[4] Univ Piemonte Orientale, Dept Clin & Expt Med, I-28100 Novara, Italy
[5] CVPath, Int Registry Pathol, Gaithersburg, MD 20878 USA
关键词
angioplasty; atherosclerosis; pathology; saphenous vein graft; stent;
D O I
10.1042/CS20070243
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of the present study was to analyse the long-term histology and immunohistochemistry of the plaque composition and cellular infiltration of SVGs (saphenous vein grafts) containing metallic stents. Percutaneous interventions in SVGs have a worse long-term clinical outcome compared with stenting of coronary arteries. Whether the pathological features of old degenerated SVGs condition the efficacy of drug-eluting stents is also unknown. Histology and immunohistochemistry of seven SVGs in the coronary circulation containing 12 metallic stents implanted 5 to 61 months before retrieval were analysed in patients undergoing a second aorto-coronary bypass surgery at a mean time of 11 + 6 years. The pathology of the old SVGs showed an important thrombotic and necrotic composition of the plaque, with plaque protrusion through the stent wires and a fragile media layer that could easily be damaged by stent placement with subsequent neointimal proliferation; indeed, stents with medial fracture had significantly greater mean neointimal thickness than those without (1.37 +/- 0.68 compared with 0.81 +/- 0.47 mm(2); P < 0.02). Neointimal inflammatory cell density correlated with increased neointimal thickness in patent vessels (r(2) =0.43, P<0.001). Immunostaining showed the total absence of ERs (oestrogen receptors), a poor cellular proliferative state as indicated by the presence of the Ki-67 marker, and persistent inflammation close to the stent wires as revealed by KP-I and ACE (angiotensin-converting enzyme) immunostaining in most inflammatory cells in contact with the metal. These pathological findings may contribute to the more severe progression of disease and worse clinical outcome observed after conventional stented angioplasty of SVGs and might also interfere with the efficacy of drug-eluting stents in this specific atherosclerotic milieu.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 30 条
[1]   VASCULAR PATHOLOGY OF BALLOON-EXPANDABLE FLEXIBLE COIL STENTS IN HUMANS [J].
ANDERSON, PG ;
BAJAJ, RK ;
BAXLEY, WA ;
ROUBIN, GS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) :372-381
[2]   Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts [J].
Baim, DS ;
Wahr, D ;
George, B ;
Leon, MB ;
Greenberg, J ;
Cutlip, DE ;
Kaya, U ;
Popma, JJ ;
Ho, KKL ;
Kuntz, RE .
CIRCULATION, 2002, 105 (11) :1285-1290
[3]   ESTROGEN AND PROGESTERONE RECEPTORS IN VESSEL WALLS - BIOCHEMICAL AND IMMUNOCHEMICAL ASSAYS [J].
BERGQVIST, A ;
BERGQVIST, D ;
FERNO, M .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1993, 72 (01) :10-16
[4]   Differential action of angiotensin II and activity of angiotensin-converting enzyme in human bypass grafts [J].
Borland, JAA ;
Chester, AH ;
Crabbe, S ;
Parkerson, JB ;
Catravas, JD ;
Yacoub, MH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (02) :206-212
[5]   Targeted stent use in clinical practice based on evidence from the BAsel Stent Cost Effectiveness Trial (BASKET) [J].
Brunner-La Rocca, Hans-Peter ;
Kaiser, Christoph ;
Pfisterer, Matthias .
EUROPEAN HEART JOURNAL, 2007, 28 (06) :719-725
[6]   Coronary artery endothelial protection after local delivery of 17β-estradiol during balloon angioplasty in a porcine model:: A potential new pharmacologic approach to improve endothelial function [J].
Chandrasekar, B ;
Nattel, S ;
Tanguay, JF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (05) :1570-1576
[7]   Long-term clinical outcome after endoluminal reconstruction of diffusely degenerated saphenous vein grafts with less-shortening Wallstents [J].
Choussat, R ;
Black, AJR ;
Bossi, I ;
Joseph, T ;
Fajadet, J ;
Marco, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (02) :387-394
[8]   Molecular basis of restenosis and drug-eluting stents [J].
Costa, MA ;
Simon, DI .
CIRCULATION, 2005, 111 (17) :2257-2273
[9]   Pathology of restenosis in saphenous bypass grafts after long-term stent implantation [J].
Depre, C ;
Havaux, X ;
Wijns, W .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 110 (03) :378-384
[10]  
Depre C, 1996, CATHETER CARDIO DIAG, V39, P215, DOI 10.1002/(SICI)1097-0304(199611)39:3<215::AID-CCD1>3.0.CO