Determination of glomerular filtration rate per unit renal volume using computerized tomography: Correlation with conventional measures of total and divided renal function

被引:51
作者
Tsushima, Y
Blomley, MJK
Okabe, K
Tsuchiya, K
Aoki, J
Endo, K
机构
[1] Motojima Gen Hosp, Dept Radiol, Gunma 3730033, Japan
[2] Motojima Gen Hosp, Dept Urol, Gunma 3730033, Japan
[3] Hemmersmith Hosp, Imperial Coll Sch Med, Dept Imaging, London, England
[4] Gunma Univ Hosp, Dept Diagnost Radiol & Nucl Med, Gunma, Japan
关键词
kidney; glomerular filtration rate; tomography; x-ray computed; contrast media;
D O I
10.1097/00005392-200102000-00007
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Previous studies suggest that functional computerized tomography (CT) can measure glomerular filtration rate (GFR) per unit renal volume. We compared this index with conventionally determined GFR measurements. Materials and Methods: A total of 16 men and 8 women 63.3 +/- 14.9 years old (range 31 to 88) were studied using with contrast enhanced CT. A single slice of kidney was scanned sequentially after bolus injection (0.5 to 1.0 ml. per second(-1)) of 20 ml. iopamidol (300 mg. iodine per ml.-l). GFR per volume of kidney was calculated using a Patlak graphical analysis and this index was multiplied by renal volume on CT to yield global GFR (ml. per minute(-1)). Divided function was also calculated. GFR and divided renal function were calculated in all cases from radioisotope renography with (99m) diethylenetetraminepentaacetic acid. In 12 subjects in whom 24-hour urine collection was possible GFR was also calculated from creatinine clearance. Results: A strong correlation was observed between divided renal function, expressed with respect to the right kidney calculated from CT (52.7 +/- 14.8%, range 19.9% to 97.4%) and by radioisotope renography (51.7 +/- 14.6%, range 18.9% to 92.6%, r = 0.97, p <0.0001). A strong correlation (r = 0.92, p <0.0001) was also seen between global GFR determined by CT (80.1 +/- 43.9 ml. per minute(-1), range 38.2 to 197.9) and creatinine clearance (72.4 +/- 47.5, range 14.6 to 168.5), and was stronger than the correlation between the radioisotope and creatinine clearance method (r = 0.67, p = 0.02) in the same patients. Conclusion: Functional CT using nonionic contrast material can measure GFR normalized to renal volume and is an accurate alternative to conventional methods of renal function evaluation.
引用
收藏
页码:382 / 385
页数:4
相关论文
共 24 条
[1]   ANALYSIS OF RADIOCONTRAST-INDUCED NEPHROPATHY BY DUAL-LABELED RADIONUCLIDE CLEARANCE [J].
ALBERT, SG ;
SHAPIRO, MJ ;
BROWN, WW ;
GOODGOLD, H ;
ZUCKERMAN, D ;
DURHAM, R ;
KERN, M ;
FLETCHER, J ;
WOLVERSON, M ;
PLUMMER, ES ;
BAUE, AE .
INVESTIGATIVE RADIOLOGY, 1994, 29 (06) :618-623
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Functional renal perfusion imaging with colour mapping:: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)? [J].
Blomley, MJK ;
McBride, A ;
Mohammedtagi, S ;
Albrecht, T ;
Harvey, CJ ;
Jäger, R ;
Standfield, NJ ;
Dawson, P .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 30 (03) :214-220
[4]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[5]   DOSING OF CONTRAST MATERIAL TO PREVENT CONTRAST NEPHROPATHY IN PATIENTS WITH RENAL-DISEASE [J].
CIGARROA, RG ;
LANGE, RA ;
WILLIAMS, RH ;
HILLIS, LD .
AMERICAN JOURNAL OF MEDICINE, 1989, 86 (06) :649-652
[6]   DYNAMIC CONTRAST BOLUS COMPUTED-TOMOGRAPHY FOR THE ASSESSMENT OF RENAL-FUNCTION [J].
DAWSON, P ;
PETERS, M .
INVESTIGATIVE RADIOLOGY, 1993, 28 (11) :1039-1042
[7]  
FRENNBY B, 1995, ACTA RADIOL, V36, P410
[8]   Application of newer clearance techniques for the determination of glomerular filtration rate [J].
Gaspari, F ;
Perico, N ;
Remuzzi, G .
CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 1998, 7 (06) :675-680