Astra Tech, Branemark, and ITI Implants in the Rehabilitation of Partial Edentulism: Two-Year Results

被引:27
作者
Bilhan, Hakan [3 ]
Kutay, Omer [3 ]
Arat, Selda [3 ]
Cekici, Ali [4 ]
Cehreli, Murat Cavit [1 ,2 ]
机构
[1] CosmORAL Oral Polyclin, Sect Prosthodont, TR-06680 Ankara, Turkey
[2] Dent Hlth Polyclin, Sect Prosthodont, TR-06680 Ankara, Turkey
[3] Istanbul Univ, Dept Removable Prosthodont, Fac Dent, Istanbul, Turkey
[4] Istanbul Univ, Dept Periodontol, Fac Dent, Istanbul, Turkey
关键词
dental implants; fixed prostheses; conventional loading; osseointegration; marginal bone loss; BONE; INTEGRATION; SURVIVAL; TISSUE;
D O I
10.1097/ID.0b013e3181f57110
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Purpose: To explore the soft tissue, marginal bone, and prosthetic complications (if any) of Astra Tech, Branemark, and ITI implants supporting fixed prostheses during an observation period of 2 years. Materials: The study comprised 26 patients, who received 42 Astra Tech, 36 Branemark, and 29 ITI implants. After 3 months of healing, abutment connections were performed for Astra Tech and Branemark implants, and fixed prostheses were delivered to the patients at 4 months. At 6-month, 1-year, and 2-year recall appointments, plaque index, periimplant inflammation index, and bleeding index scores, were recorded. The marginal bone levels were also measured at 2-year recall by means of radiographic evaluation, and prosthetic complications were recorded throughout the study. Results: All implants survived during the 2-year observation period. The plaque index and periimplant inflammation index scores around Branemark implants were higher than ITI and Astra Tech implants in the first year of function (P > 0.05). Marginal bone loss around ITI and Astra Tech implants was similar at 2 years (P > 0.05). The marginal bone loss around Branemark implants was higher than Astra Tech implants (P > 0.05) but similar to ITI implants at 2-year recall appointment (P > 0.05). Fixed prostheses supported by ITI and Astra Tech implants did not experience prosthetic complications, and only 1 patient of the Branemark group had porcelain veneer fracture. Conclusions: Astra Tech, Branemark, and ITI implants supporting fixed prostheses had same survival rates (100%) in this study. ITI and Astra Tech implants had similar changes in marginal bone levels, whereas Branemark implants had higher marginal bone loss, particularly in the first year of function. (Implant Dent 2010;19:437-446)
引用
收藏
页码:437 / 446
页数:10
相关论文
共 29 条
[1]
The peri-implant hard and soft tissues at different implant systems - A comparative study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Wennstrom, J ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :212-219
[2]
The mucosal barrier following abutment dis/reconnection - An experimental study in dogs [J].
Abrahamsson, I ;
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (08) :568-572
[3]
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[4]
*AN ASO, 1998, ANESTHESIOLOGY, V234, P111
[5]
Astrand P, 1999, Clin Implant Dent Relat Res, V1, P17, DOI 10.1111/j.1708-8208.1999.tb00087.x
[6]
Astra Tech and Branemark system implants:: a 5-year prospective study of marginal bone reactions [J].
Åstrand, P ;
Engquist, B ;
Dahlgren, S ;
Gröndahl, K ;
Engquist, E ;
Feldmann, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :413-420
[7]
Astrand Per, 2004, Clin Implant Dent Relat Res, V6, P130, DOI 10.1111/j.1708-8208.2004.tb00213.x
[8]
Astrand Per, 2002, Clin Implant Dent Relat Res, V4, P115, DOI 10.1111/j.1708-8208.2002.tb00161.x
[9]
Bone reactions to longstanding functional load at implants: an experimental study in dogs [J].
Berglundh, T ;
Abrahamsson, I ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (09) :925-932
[10]
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1