Global analysis of unmatched polarized fluorescence decay curves of systems exhibiting a residual anisotropy at long times

被引:7
作者
Dutt, GB
Ameloot, M
Bernik, D
Negri, RM
DeSchryver, FC
机构
[1] LIMBURGS UNIV CENTRUM,B-3590 DIEPENBEEK,BELGIUM
[2] KATHOLIEKE UNIV LEUVEN,DEPT SCHEIKUNDE,LAB MOL DYNAM & SPECT,B-3001 LOUVAIN,BELGIUM
关键词
D O I
10.1021/jp960085j
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A previous study of the performance of the global, i.e., simultaneous, analysis of unmatched polarized decay traces [Crutzen, M.; et al. J. Phys. Chem. 1993, 97, 8133] is extended for the time-dependent anisotropy r(t), given by r(t) = beta exp(-t/Phi) + r infinity. The evaluation was done with computer-generated and experimentally collected data. Two different schemes of analysis of unmatched polarized decay traces were considered. In scheme A the decay curves measured with the analyzer set at 0 degrees, 54.7 degrees, and 90 degrees with respect to the polarization of the incident light were globally analyzed, while only the traces at 0 degrees and 90 degrees were taken into account in scheme B. Data were simulated for various Phi/tau ratios (0.1, 1, 3, and 10). The value obtained for the fluorescence lifetime tau was accurate and precise for all cases considered. For Phi/tau = 0.1, 1, and 3 (tau = 5 ns) the parameters beta and Phi, were well recovered. The accuracy and precision were very similar to the results obtained with matched decay traces. The recovery of r infinity was case dependent. Scheme A performed somewhat better than scheme B. When r(0) was fixed to the true value, the analysis with schemes A and B yielded the same accuracy and precision as the analysis of the matched curves. For Phi/tau = 10, the parameter estimates for the anisotropy parameters were inaccurate and suffered from very high uncertainty. No improvement was obtained when r(0) and the matching factors were kept fixed to the true value. This is in contrast with the results obtained for r(t) without an r infinity term, where Phi/tau can even be much higher when r(0) or the matching factors are kept fixed. There was some improvement when the signal to noise ratio was increased. When the decay of the total fluorescence was biexponential, scheme A performed much better than scheme B. The best results were obtained when G or r(0) was kept fixed. It was found that with respect to the normalization of the polarized decay traces the fundamental anisotropy r(0) and the matching factor G contain the same information. In general, the best accuracy and precision in the parameter recovery were obtained when a predetermined value for G or r(0) was used in the analysis. The performance of the analyses without the information on r(0) or G depended more on the Phi/tau ratio than for the analyses where this information was used. Fixing of both G and r(0) to the proper value might lead to an improved precision. It has to be emphasized that the use of incorrect values for G (with r(0) freely adjustable) or r(0) (with G freely adjustable) could lead to good data fits, although the parameter estimates are incorrect. A small change in r(0) can lead to a large change in Phi. Therefore, in general it can be recommended that either G or r(0) be fixed, but not both. Alternatively, the comparison of the results obtained with a freely adjustable G and a fixed G can provide a check for the data analysis.
引用
收藏
页码:9751 / 9761
页数:11
相关论文
共 57 条
[1]   EXTENSION OF THE PERFORMANCE OF LAPLACE DECONVOLUTION IN THE ANALYSIS OF FLUORESCENCE DECAY CURVES [J].
AMELOOT, M ;
HENDRICKX, H .
BIOPHYSICAL JOURNAL, 1983, 44 (01) :27-38
[2]   EFFECT OF ORIENTATIONAL ORDER ON THE DECAY OF THE FLUORESCENCE ANISOTROPY IN MEMBRANE SUSPENSIONS - EXPERIMENTAL-VERIFICATION ON UNILAMELLAR VESICLES AND LIPID ALPHA-LACTALBUMIN COMPLEXES [J].
AMELOOT, M ;
HENDRICKX, H ;
HERREMAN, W ;
POTTEL, H ;
VANCAUWELAERT, F ;
VANDERMEER, W .
BIOPHYSICAL JOURNAL, 1984, 46 (04) :525-539
[3]   USE OF REGULARIZATION OPERATORS TOGETHER WITH LAGRANGE MULTIPLIERS IN NUMERICAL DECONVOLUTION OF FLUORESCENCE DECAY CURVES [J].
ANDRE, JC ;
BOUCHY, M ;
VIOVY, JL ;
VINCENT, LM ;
VALEUR, B .
COMPUTERS & CHEMISTRY, 1982, 6 (01) :5-13
[4]  
[Anonymous], 1983, EXCITED STATE LIFETI
[5]   INTENSITY DECONVOLUTION IN FLUORESCENCE DEPOLARIZATION STUDIES OF LIQUIDS, LIQUID-CRYSTALS AND MEMBRANES [J].
ARCIONI, A ;
ZANNONI, C .
CHEMICAL PHYSICS, 1984, 88 (01) :113-128
[6]   NEW METHOD FOR CURVE FITTING TO THE DATA WITH LOW STATISTICS NOT USING THE CHI-2-METHOD [J].
AWAYA, T .
NUCLEAR INSTRUMENTS & METHODS, 1979, 165 (02) :317-323
[7]  
Beechem J. M., 2002, TOPICS FLUORESCENCE, P241, DOI DOI 10.1007/0-306-47058-6_5
[8]   GLOBAL ANALYSIS OF FLUORESCENCE DECAY - APPLICATIONS TO SOME UNUSUAL EXPERIMENTAL AND THEORETICAL-STUDIES [J].
BEECHEM, JM ;
BRAND, L .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1986, 44 (03) :323-329
[9]  
BEECHEM JM, 1985, ANAL INSTRUM, V14, P379
[10]   THE SOLUTE SIZE EFFECT IN ROTATIONAL DIFFUSION EXPERIMENTS - A TEST OF MICROSCOPIC FRICTION THEORIES [J].
BENAMOTZ, D ;
DRAKE, JM .
JOURNAL OF CHEMICAL PHYSICS, 1988, 89 (02) :1019-1029