On-line solid-phase extraction liquid chromatography, particle beam mass spectrometry, and gas chromatography mass spectrometry of carbamate pesticides

被引:24
作者
Slobodnik, J
HoekstraOussoren, SJF
Jager, ME
Honing, M
vanBaar, BLM
Brinkman, UAT
机构
[1] CSIC,CID,DEPT ENVIRONM CHEM,BARCELONA 08034,SPAIN
[2] FREE UNIV AMSTERDAM,DEPT ORGAN & INORGAN CHEM,NL-1081 HV AMSTERDAM,NETHERLANDS
关键词
on-line solid-phase extraction; column liquid chromatography; gas chromatography; mass spectrometry; carbamate pesticides; environmental samples;
D O I
10.1039/an9962101327
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line solid-phase extraction-liquid chromatography-particle beam mass spectrometry (SPE-LC-PB-MS) was used to study 32 carbamates and 11 of their transformation products in environmental water samples, The analytes were enriched from 100 ml samples on Bondesil-C-18/OH, packed in a 10 mm x 3.0 mm id precolumn, eluted on-line with a gradient of methanol-0.1 mol l(-1) ammonium acetate to a C-18 analytical column and detected by PB-MS, Detection limits of 12 carbamates and five degradation products were 0.1-8 mu g l(-1) in surface water, using full-scan electron impact mode detection, The RSDs of the retention times were 0.05-0.2% and those of peak areas 5-35%, Twenty-eight analytes proved to be amenable to GC with detection limits of 0.05-3 ng injected on-column, When using the same mass spectrometer, the spectra obtained by LC-PB-MS and GC-MS were identical.
引用
收藏
页码:1327 / 1334
页数:8
相关论文
共 38 条
[11]  
GRAVES RL, 1989, MEASUREMENT N METHYL
[12]   COMPARISON OF REVERSED-PHASE EXTRACTION SORBENTS FOR THE ONLINE TRACE ENRICHMENT OF POLAR ORGANIC-COMPOUNDS IN ENVIRONMENTAL AQUEOUS SAMPLES [J].
HENNION, MC ;
COQUART, V .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :211-224
[13]   DETERMINATION OF N-METHYLCARBAMATE PESTICIDES IN ENVIRONMENTAL WATER SAMPLES USING AUTOMATED ONLINE TRACE ENRICHMENT WITH EXCHANGEABLE CARTRIDGES AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HIEMSTRA, M ;
DEKOK, A .
JOURNAL OF CHROMATOGRAPHY A, 1994, 667 (1-2) :155-166
[14]   MASS-TRANSPORT AND CALIBRATION IN LIQUID-CHROMATOGRAPHY PARTICLE BEAM MASS-SPECTROMETRY [J].
HO, JS ;
BEHYMER, TD ;
BUDDE, WL ;
BELLAR, TA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (06) :662-671
[15]   EFFECT OF ION-SOURCE PRESSURE AN ION FORMATION OF CARBAMATES IN PARTICLE-BEAM CHEMICAL-IONIZATION MASS-SPECTROMETRY [J].
HONING, M ;
BARCELO, D ;
JAGER, ME ;
SLOBODNIK, J ;
VANBAAR, BLM ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :21-30
[16]  
HONING M, 1995, QUALITY ASSURANCE EN, P535
[17]  
*J WIL SONS, 1996, WIL STAND MASS SPECT
[18]   AMMONIA AND METHANE CHEMICAL IONIZATION MASS-SPECTRA OF ACID AND CARBAMATE PESTICIDES USING DIRECT SUPERCRITICAL FLUID INJECTION [J].
KALINOSKI, HT ;
WRIGHT, BW ;
SMITH, RD .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1986, 13 (01) :33-45
[19]   Eluent jet interface for combining capillary liquid flows with electron impact mass spectrometry [J].
Kientz, CE ;
Hulst, AG ;
DeJong, AL ;
Wils, ERJ .
ANALYTICAL CHEMISTRY, 1996, 68 (04) :675-681
[20]  
KRAUSE RT, 1988, J CHROMATOGR, V442, P333, DOI 10.1016/S0021-9673(00)94481-9