Chemometric analysis of complex hyphenated data - Improvements of the component detection algorithm

被引:19
作者
Windig, W.
Smith, W. F.
机构
[1] Eigenvector Res Inst, Wenatchee, WA 98801 USA
[2] Eastman Kodak Co, Rochester, NY 14650 USA
关键词
chemometrics; CODA; liquid chromatography/mass spectrometry; baseline correction;
D O I
10.1016/j.chroma.2007.03.081
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Component detection algorithm (CODA) is a method to quickly extract the high-quality mass chromatograms from complex liquid chromatography/electrospray ionization mass spectrometry (LC/MS) data sets, saving operators hours of analysis time. It appeared, however, that mass chromatograms with a limited baseline problem were ignored. This paper describes several methods to increase the tolerance for mass chromatograms with a baseline. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:251 / 257
页数:7
相关论文
共 17 条
[1]   A universal denoising and peak picking algorithm for LC-MS based on matched filtration in the chromatographic time domain [J].
Andreev, VP ;
Rejtar, T ;
Chen, HS ;
Moskovets, EV ;
Ivanov, AR ;
Karger, BL .
ANALYTICAL CHEMISTRY, 2003, 75 (22) :6314-6326
[2]  
ANTLER M, 2004, INTRO CODA ADV CHEM
[3]   Comparison between liquid chromatography-UV detection and liquid chromatography-mass spectrometry for the characterization of impurities and/or degradants present in trimethoprim tablets [J].
Barbarin, N ;
Henion, JD ;
Wu, YH .
JOURNAL OF CHROMATOGRAPHY A, 2002, 970 (1-2) :141-154
[4]   Windowed mass selection method: a new data processing algorithm for liquid chromatography-mass spectrometry data [J].
Fleming, CM ;
Kowalski, BR ;
Apffel, A ;
Hancock, WS .
JOURNAL OF CHROMATOGRAPHY A, 1999, 849 (01) :71-85
[5]   Analysis of human serum by liquid chromatography-mass spectrometry: Improved sample preparation and data analysis [J].
Govorukhina, N. I. ;
Reijmers, T. H. ;
Nyangoma, S. O. ;
van der Zee, A. G. J. ;
Jansen, R. C. ;
Bischoff, R. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) :142-150
[6]  
*JEOL, 1999, MS111999A JEOL
[7]   Autoregressive modeling of analytical sensor data can yield classifiers in the predictor coefficient parameter space [J].
Krebs, MD ;
Tingley, RD ;
Zeskind, JE ;
Kang, JM ;
Holmboe, ME ;
Davis, CE .
BIOINFORMATICS, 2005, 21 (08) :1325-1331
[8]   APPLICATION OF SEQUENTIAL PAIRED COVARIANCE TO CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY - UNRAVELING THE SIGNAL FROM THE NOISE IN THE ELECTROPHEROGRAM [J].
MUDDIMAN, DC ;
ROCKWOOD, AL ;
GAO, Q ;
SEVERS, JC ;
UDSETH, HR ;
SMITH, RD ;
PROCTOR, A .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4371-4375
[9]   Application of sequential paired covariance to liquid chromatography mass spectrometry data - Enhancements in both the signal-to-noise ratio and the resolution of analyte peaks in the chromatogram [J].
Muddiman, DC ;
Huang, BM ;
Anderson, GA ;
Rockwood, A ;
Hofstadler, SA ;
WeirLipton, MS ;
Proctor, A ;
Wu, QY ;
Smith, RD .
JOURNAL OF CHROMATOGRAPHY A, 1997, 771 (1-2) :1-7
[10]  
RECH D, 2004, P 3 BRAZ WORKSH BIOI, P158