Reliable determination of freeze-concentration using DSC

被引:31
作者
Bhatnagar, BS
Cardon, S
Pikal, MJ
Bogner, RH
机构
[1] Univ Connecticut, Sch Pharm, Storrs, CT 06269 USA
[2] Univ Connecticut, Inst Mat Sci, Storrs, CT 06269 USA
关键词
sucrose; DSC; freeze-concentration; T-offsett; ice melting;
D O I
10.1016/j.tca.2004.06.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
The objective of this study was to determine the feature of a DSC endotherm that can be most reliably used to determine the composition of a freeze-concentrate. Samples (3-10 mg) of sucrose in water (0-60%, w/v) were frozen and then heated (at 0.2-2.0 degreesC/min) on a DSC. The peak (T-peak) and offset (T-offset) temperatures were obtained from the melt endotherms. A freezing point osmometer was also used to determine the freezing point depression of sucrose solutions. Two theoretical models were developed, one that describes melting in a one-component system (ice) with a heterogeneous temperature distribution, and a second model, which describes melting in a binary system (sucrose and ice) with a homogeneous temperature distribution. Modeling Laboratory (MLAB) was used to simulate melt endotherms using the two models. In Gray's theory for analysis of dynamic thermal measurement (1968), the end of the melting occurs at the peak of the endotherm followed by a much sharper recovery to the baseline than that observed experimentally. Our theoretical model for one- and two-component systems predicts that the melting continues beyond the peak resulting in a delayed recovery to the baseline as experimentally observed. Both experimental and simulated T-peak and T-offset (also defined as the return to the baseline after completion of the peak) increased with an increasing scan rate. Extrapolation of the experimental T-offset to a zero scan rate yielded a value of the equilibrium melting temperature, T-m, which is closer to accepted literature values and osmometry data than did the extrapolation of T-peak. Neither T-peak nor T-offset reliably (at a finite scan rate) define the multicomponent freezing point. Rather, an extrapolation of T-offset to a zero scan rate gives the most reliable measure of freezing point using DSC. Simulation of DSC endotherms supports this conclusion and also exhibits the same trends as observed from experiment. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 163
页数:15
相关论文
共 28 条
[1]   DIFFERENTIAL SCANNING CALORIMETRIC STUDY OF FROZEN SUCROSE AND GLYCEROL SOLUTIONS [J].
ABLETT, S ;
IZZARD, MJ ;
LILLFORD, PJ .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1992, 88 (06) :789-794
[2]  
[Anonymous], IZV AKAD NAUK SSSR
[3]   Modeling of the water-sucrose state diagram below 0 degrees C [J].
Blond, G ;
Simatos, D ;
Catte, M ;
Dussap, CG ;
Gros, JB .
CARBOHYDRATE RESEARCH, 1997, 298 (03) :139-145
[4]  
EWAN T, 1899, Z PHYS CHEM, V31, P22
[5]   CORRECTION FOR SOLUTE/SOLVENT INTERACTION EXTENDS ACCURATE FREEZING-POINT DEPRESSION THEORY TO HIGH-CONCENTRATION RANGE [J].
FULLERTON, GD ;
KEENER, CR ;
CAMERON, IL .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1994, 29 (3-4) :217-235
[6]  
Gray A.P., 1968, ANAL CALORIMETRY, P209
[7]   DETERMINATION OF THE UNFROZEN WATER-CONTENT OF MAXIMALLY FREEZE-CONCENTRATED CARBOHYDRATE SOLUTIONS [J].
HATLEY, RHM ;
MANT, A .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 1993, 15 (04) :227-232
[8]   MEASUREMENT OF GLASS-TRANSITION TEMPERATURES OF FREEZE-CONCENTRATED SOLUTES BY DIFFERENTIAL SCANNING CALORIMETRY [J].
HER, LM ;
NAIL, SL .
PHARMACEUTICAL RESEARCH, 1994, 11 (01) :54-59
[9]   Freeze-concentration separates proteins and polymer excipients into different amorphous phases [J].
Izutsu, K ;
Kojima, S .
PHARMACEUTICAL RESEARCH, 2000, 17 (10) :1316-1322
[10]  
Luyet B, 1968, Biodynamica, V10, P167