Effect of contrast dose and field strength in the magnetic resonance detection of brain metastases

被引:82
作者
Ba-Ssalamah, A
Nöbauer-Huhmann, IM
Pinker, K
Schibany, N
Prokesch, R
Mehrain, S
Mlynárik, V
Fog, A
Heimberger, K
Trattnig, S
机构
[1] Univ Vienna, Dept Radiol, A-1090 Vienna, Austria
[2] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
[3] Amersham Hlth, Med & Profess Serv Europe Int, London, England
关键词
3 T MRI; high field strength; single dose and cumulative triple dose; MRI contrast agent; brain metastases;
D O I
10.1097/00004424-200307000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the diagnostic efficacy of a standard and cumulative triple dose of magnetic resonance (MR) imaging contrast agent in the evaluation of brain metastases using a high-field 3.0 T MR unit versus a standard field 1.5 T MR unit. Methods: Twenty-two patients with suspected brain metastases were examined at both field strengths using identical postcontrast coronal 3D gradient echo with magnetization preparation, which was adjusted separately for each field strength. In both groups initially, iv injection of 0.1 mmol/kg body weight gadolinium chelate (gadodiamide) and thereafter, 0.2 mmol/kg body weight gadodiamide were administered. Subjective assessment of the images was performed independently by 3 neuroradiologists. Objective measurement of signal-to-noise and contrast-to-noise ratios was obtained. Results: The subjective assessment of cumulative triple-dose 3.0 T images obtained the best results compared with other sequences, detecting 84 metastases, followed by 1.5 T cumulative triple-dose enhanced images with 81 brain metastases. The objective assessment confirmed those results, showing significantly higher signal-to-noise and contrast-to-noise ratios with 3.0 T than with 1.5 T. Conclusions: Cumulative triple-dose images of both field strengths were superior to standard field strengths. However, administration of gadodiamide contrast agent produces higher contrast between tumor and normal brain on 3.0 T than on 1.5 T, resulting in better detection of brain metastases and leptomeningeal involvement.
引用
收藏
页码:415 / 422
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 1978, ADV NEUROL
[2]   Enhancement of cerebral diseases: How much contrast agent is enough? Comparison of 0.1, 0.2, and 0.3 mmol/kg gadoteridol at 0.2 T with 0.1 mmol/kg gadoteridol at 1.5 T [J].
Brekenfeld, C ;
Foert, E ;
Hundt, W ;
Kenn, W ;
Lodeann, KP ;
Gehl, HB .
INVESTIGATIVE RADIOLOGY, 2001, 36 (05) :266-275
[3]  
CHANG KH, 1994, AM J NEURORADIOL, V15, P1413
[4]   MAGNETIC-RESONANCE IMAGING - EFFECTS OF MAGNETIC-FIELD STRENGTH [J].
CROOKS, LE ;
ARAKAWA, M ;
HOENNINGER, J ;
MCCARTEN, B ;
WATTS, J ;
KAUFMAN, L .
RADIOLOGY, 1984, 151 (01) :127-133
[5]  
DAVIS PC, 1991, AM J NEURORADIOL, V12, P293
[6]   DISTRIBUTION OF BRAIN METASTASES [J].
DELATTRE, JY ;
KROL, G ;
THALER, HT ;
POSNER, JB .
ARCHIVES OF NEUROLOGY, 1988, 45 (07) :741-744
[7]   USE OF MAGNETIZATION-TRANSFER FOR IMPROVED CONTRAST ON GRADIENT-ECHO MR-IMAGES OF THE CERVICAL-SPINE [J].
FINELLI, DA ;
HURST, GC ;
KARAMAN, BA ;
SIMON, JE ;
DUERK, JL ;
BELLON, EM .
RADIOLOGY, 1994, 193 (01) :165-171
[8]  
HAUSTEIN J, 1992, AM J NEURORADIOL, V13, P1199
[9]   INCREASED DETECTION OF INTRACRANIAL METASTASES WITH INTRAVENOUS GD-DTPA [J].
HEALY, ME ;
HESSELINK, JR ;
PRESS, GA ;
MIDDLETON, MS .
RADIOLOGY, 1987, 165 (03) :619-624
[10]  
LINDSEY RO, 1994, AM J NEURORADIOL, V15, P1849