Identifying potential biomarkers in LC-MS data

被引:15
作者
Daszykowski, M.
Wu, W.
Nicholls, A. W.
Ball, R. J.
Czekaj, T.
Walczak, B.
机构
[1] Silesian Univ, Dept Chemometr, Inst Chem, PL-40006 Katowice, Poland
[2] GlaxoSmithKline, Bioinformat Sci, Stevenage SG1 2NY, Herts, England
[3] GlaxoSmithKline, Investigat Preclin Toxicol, Ware SG12 0DP, Herts, England
关键词
UVE-PLS; background removal; noise reduction; variable selection;
D O I
10.1002/cem.1066
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper an application of the uninformative variable elimination-partial least squares (UVE-PLS) method extended by the Monte Carlo approach for selection of possible biomarkers from the liquid chromatography coupled with mass spectrometry (LC-MS) data is reported. The main challenge consists not in the chemometrics analysis of LC-MS data, but in the data organization. However, as demonstrated in our study, the selected variables are similar regardless of the data organization strategy. The best results are obtained for the standard normal variate (SNV) transformed data. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:292 / 302
页数:11
相关论文
共 24 条
[1]   A comprehensive approach to the analysis of matrix-assisted laser desorption/ionization-time of flight proteomics spectra from serum samples [J].
Baggerly, KA ;
Morris, JS ;
Wang, J ;
Gold, D ;
Xiao, LC ;
Coombes, KR .
PROTEOMICS, 2003, 3 (09) :1667-1672
[2]   Partial least squares for discrimination [J].
Barker, M ;
Rayens, W .
JOURNAL OF CHEMOMETRICS, 2003, 17 (03) :166-173
[3]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[4]   Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography-mass spectrometry data [J].
Bylund, D ;
Danielsson, R ;
Malmquist, G ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (02) :237-244
[5]   Elimination of uninformative variables for multivariate calibration [J].
Centner, V ;
Massart, DL ;
deNoord, OE ;
deJong, S ;
Vandeginste, BM ;
Sterna, C .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3851-3858
[6]   Metabolic fingerprinting of rat urine by LC/MS Part 2. Data pretreatment methods for handling of complex data [J].
Idborg, H ;
Zamani, L ;
Edlund, PO ;
Schuppe-Koistinen, I ;
Jacobsson, SP .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2) :14-20
[7]   Multivariate approaches for efficient detection of potential metabolites from liquid chromatography/mass spectrometry data [J].
Idborg, H ;
Edlund, PO ;
Jacobsson, SP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (09) :944-954
[8]   Screening of biomarkers in rat urine using LC/electrospray ionization-MS and two-way data analysis [J].
Idborg-Björkman, H ;
Edlund, PO ;
Kvalheim, OM ;
Schuppe-Koistinen, I ;
Jacobsson, SP .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4784-4792
[9]   Extraction, interpretation and validation of information for comparing samples in metabolic LC/MS data sets [J].
Jonsson, P ;
Bruce, SJ ;
Moritz, T ;
Trygg, J ;
Sjöström, M ;
Plumb, R ;
Granger, J ;
Maibaum, E ;
Nicholson, JK ;
Holmes, E ;
Antti, H .
ANALYST, 2005, 130 (05) :701-707