Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials

被引:67
作者
Hoffmann, R. [1 ]
Morice, M-C [2 ]
Moses, J. W. [3 ]
Fitzgerald, P. J. [4 ]
Mauri, L. [5 ]
Breithardt, G. [6 ]
Schofer, J. [7 ]
Serruys, P. W. [8 ]
Stoll, H-P [9 ]
Leon, M. B. [3 ]
机构
[1] Univ Hosp Aachen, Aachen, Germany
[2] Inst Cardiovasc Paris Sud, Massy, France
[3] Columbia Univ, Med Ctr, New York, NY USA
[4] Stanford Univ, Stanford, CA 94305 USA
[5] Harvard Univ, Brigham & Womens Hosp, Sch Med, Boston, MA 02115 USA
[6] Hosp Univ Munster, Dept Cardiol & Angiol, Munster, Germany
[7] Ctr Cardiol & Vasc Intervent, Hamburg, Germany
[8] Erasmus MC, Rotterdam, Netherlands
[9] Cordis Clin Res, Waterloo, Belgium
关键词
D O I
10.1136/hrt.2007.120154
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The impact of incomplete stent apposition (ISA) after drug-eluting stent implantation determined by intravascular ultrasound (IVUS) on late clinical events is not well defined. Objective: To evaluate the clinical impact of ISA after sirolimus-eluting stent (SES) placement during a follow-up period of 4 years. Design: Pooled analysis from the RAVEL, E-SIRIUS and SIRIUS trials, three randomised, multicentre studies comparing SES and bare-metal stents (BMS). Methods: IVUS at angiographic follow-up was available in 325 patients (SES: n = 180, BMS: n = 145). IVUS images were reviewed for the presence of ISA defined as one or more unapposed stent struts. Clinical follow-up was available for a 4-year period in all patients. Frequency, predictors and clinical sequel of ISA at follow-up after SES and BMS implantation were determined. Results: ISA at follow-up was more common after SES (n = 45 (25%)) than after BMS (n = 12 (8.3%), p<0.001). Canadian Cardiology Society class III or IV angina at stent implantation (odds ratio (OR) = 4.69, 95% CI 2.15 to 10.23, p<0.001) and absence of diabetes (OR = 3.42, 95% CI 1.05 to 11.1, p = 0.041) were predictors of ISA at follow-up after SES placement. Rate of myocardial infarction tended to be slightly higher for ISA than for non-ISA patients. When SES patients only were considered, major adverse cardiac event free survival at 4 years was identical for those with and without ISA at follow-up (11.1% vs 16.3%, p = 0.48). Conclusions: ISA at follow-up is more common after SES implantation than after BMS implantation. Considering the current very sensitive IVUS definition, ISA appears to be an IVUS finding without significant impact on the incidence of major adverse cardiac events even during long-term follow-up.
引用
收藏
页码:322 / 328
页数:7
相关论文
共 20 条
[1]   Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis [J].
Ako, J ;
Morino, Y ;
Honda, Y ;
Hassan, A ;
Sonoda, S ;
Yock, PG ;
Leon, MB ;
Moses, JW ;
Bonneau, HN ;
Fitzgerald, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) :1002-1005
[2]   What is the risk of stent thrombosis associated with the use of paclitaxel-eluting stents for percutaneous coronary intervention? A meta-analysis [J].
Bavry, AA ;
Kumbhani, DJ ;
Helton, TJ ;
Bhatt, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (06) :941-946
[3]   Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions - An intravascular ultrasound analysis [J].
Degertekin, M ;
Serruys, PW ;
Tanabe, K ;
Lee, CH ;
Sousa, JE ;
Colombo, A ;
Morice, MC ;
Ligthart, JMR ;
de Feyter, PJ .
CIRCULATION, 2003, 108 (22) :2747-2750
[4]   Vascular response to Sirolimus-Eluting Stents delivered with a NonAggressive implantation technique: Comparison of intravascular ultrasound results from the multicenter, Randomized E-SIRIUS, and SIRIUS trials [J].
Hoffmann, R ;
Guagliumi, G ;
Musumeci, G ;
Reimers, B ;
Petronio, AS ;
Disco, C ;
Amoroso, G ;
Moses, JW ;
Fitzgerald, PJ ;
Schofer, J ;
Leon, MB ;
Breithardt, G .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (04) :499-506
[5]   Late stent malapposition after drug-eluting stent implantation - An intravascular ultrasound analysis with long-term follow-up [J].
Hong, MK ;
Mintz, GS ;
Lee, CW ;
Park, DW ;
Park, KM ;
Lee, BK ;
Kim, YH ;
Song, JM ;
Han, KH ;
Kang, DH ;
Cheong, SS ;
Song, JK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
CIRCULATION, 2006, 113 (03) :414-419
[6]   Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation [J].
Hong, MK ;
Mintz, GS ;
Lee, CW ;
Kim, YH ;
Lee, SW ;
Song, JM ;
Han, KH ;
Kang, DH ;
Song, JK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
CIRCULATION, 2004, 109 (07) :881-886
[7]   Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents [J].
Iakovou, I ;
Schmidt, T ;
Bonizzoni, E ;
Ge, L ;
Sangiorgi, GM ;
Stankovic, G ;
Airoldi, F ;
Chieffo, A ;
Montorfano, M ;
Carlino, M ;
Michev, I ;
Corvaja, N ;
Briguori, C ;
Gerckens, U ;
Grube, E ;
Colombo, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17) :2126-2130
[8]   Pathology of drug-eluting stents in humans - Delayed healing and late thrombotic risk [J].
Joner, Michael ;
Finn, Aloke V. ;
Farb, Andrew ;
Mont, Erik K. ;
Kolodgie, Frank D. ;
Ladich, Elena ;
Kutys, Robert ;
Skorija, Kristi ;
Gold, Herman K. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :193-202
[9]   Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy [J].
McFadden, EP ;
Stabile, E ;
Regar, E ;
Cheneau, E ;
Ong, ATL ;
Kinnaird, T ;
Suddath, WO ;
Weissman, NJ ;
Torguson, R ;
Kent, KM ;
Pichard, AD ;
Satler, LF ;
Waksman, R ;
Serruys, PW .
LANCET, 2004, 364 (9444) :1519-1521
[10]   Regional remodeling as the cause of late stent malapposition [J].
Mintz, GS ;
Shah, VM ;
Weissman, NJ .
CIRCULATION, 2003, 107 (21) :2660-2663