Optimization of the ultrafast Look-Locker echo-planar imaging T1 mapping sequence

被引:60
作者
Freeman, AJ [1 ]
Gowland, PA [1 ]
Mansfield, P [1 ]
机构
[1] Univ Nottingham, Dept Phys, Magnet Resonance Ctr, Nottingham NG7 2RD, England
关键词
fast T-1 mapping; LL-EPI; contrast agent dynamics; optimization; enhancement;
D O I
10.1016/S0730-725X(98)00011-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Look-Locker echo-planar imaging (LL-EPI) sequence has been numerically optimized in terms of the signal-to-noise ratio in the measured value of T-1, for both single-shot (repetition time (T-R) = proportional to), and dynamically repeated T-1 measurements, The sequence is optimized for the normal biologic range of T-1 (0.2 s to 2.0 s) and for a range of sequence parameters found on most magnetic resonance (MR) scanners. Both linearly and geometrically spaced magnetization sample pulse intervals were considered, Far single-shot measurements, the sequence with 24 linearly spaced sample pulses, an inversion time of 0.01 a, an inter-sample pulse delay of 0.10 s, and a sample radiofrequency (RF) pulse flip angle of 25 degrees was found to be optimum, When the number of sample pulses was limited due to hardware limitations, different pulse sequence parameters were indicated. The optimization procedures used are appropriate for any single-shot T-1 mapping sequence variant and for any rapid T-1 mapping application. The use of an optimized Look-Locker echo-planar imaging sequence is demonstrated by an example of dynamic contrast-enhanced scanning in the brain using fast T-1 mapping. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:765 / 772
页数:8
相关论文
共 17 条
[1]   A COMPARISON OF ONE-SHOT AND RECOVERY METHODS IN T1-IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :23-34
[2]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[3]  
FREEMAN A, 1994, MAGN RESON MATER PHY, V2, P409, DOI 10.1007/BF01705285
[4]   ACCURATE MEASUREMENT OF T(1) IN-VIVO IN LESS-THAN 3 SECONDS USING ECHO-PLANAR IMAGING [J].
GOWLAND, P ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :351-354
[5]   DYNAMIC STUDIES OF GADOLINIUM UPTAKE IN BRAIN-TUMORS USING INVERSION-RECOVERY ECHO-PLANAR IMAGING [J].
GOWLAND, P ;
MANSFIELD, P ;
BULLOCK, P ;
STEHLING, M ;
WORTHINGTON, B ;
FIRTH, J .
MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (02) :241-258
[6]   A SIMPLE METHOD FOR THE RESTORATION OF SIGNAL POLARITY IN MULTIIMAGE INVERSION RECOVERY SEQUENCES FOR MEASURING T1 [J].
GOWLAND, PA ;
LEACH, MO .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) :224-231
[7]   In vivo relaxation time measurements in the human placenta using echo planar imaging at 0.5 T [J].
Gowland, PA ;
Freeman, A ;
Issa, B ;
Boulby, P ;
Duncan, KR ;
Moore, RJ ;
Baker, PN ;
Bowtell, RW ;
Johnson, IR ;
Worthington, BS .
MAGNETIC RESONANCE IMAGING, 1998, 16 (03) :241-247
[8]  
GRAUMANN R, 1987, Electromedica (English Edition), V55, P67
[9]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[10]   IMPROVEMENTS IN SNAP-SHOT NUCLEAR MAGNETIC-RESONANCE IMAGING [J].
HOWSEMAN, AM ;
STEHLING, MK ;
CHAPMAN, B ;
COXON, R ;
TURNER, R ;
ORDIDGE, RJ ;
CAWLEY, MG ;
GLOVER, P ;
MANSFIELD, P ;
COUPLAND, RE .
BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (729) :822-828