Endovascular stent-graft treatment of traumatic arterial lesions

被引:184
作者
Parodi, JC
Schönholz, C
Ferreira, LM
Bergan, J
机构
[1] Inst Cardiovasc Buenos Aires, Dept Vasc Surg, RA-1428 Buenos Aires, DF, Argentina
[2] Clin La Sagrada Familia, Dept Intervent Radiol, Capital Fed, Argentina
[3] Scripps Mem Hosp, Dept Surg, La Jolla, CA USA
关键词
D O I
10.1007/s100169900230
中图分类号
R61 [外科手术学];
学科分类号
摘要
Twenty-nine cases of post-traumatic false aneurysms and arteriovenous fistulas (AVF), with a mean follow-up of 24 months (1-65 months), are presented here. Diagnosis was established by color duplex and arteriogram. The time between injury and treatment varied between 3 days and 61 months. Endovascular treatment was accomplished using a covered Palmaz stent [vein, polytetrafluoroethylene (PTFE), or polyester], Corvita endoluminal graft, or a Wallgraft. Complimentary treatment of a branch injury was performed using a detachable balloon in one patient. The initial result was favorable for all patients. One case of asymptomatic stenosis of an iliac stent graft and three occlusions of the stent (one subclavian, one axillary, and one internal carotid) were registered during the follow-up period, and no clinical manifestations of the occlusions were reported. Endovascular treatment of post-traumatic false aneurysms and AVF appears to be a promising alternative for treatment of these lesions. Less pain and disability as well as rapid recovery time and lower cost after endovascular treatment compare favorably to the standard surgical technique.
引用
收藏
页码:121 / 129
页数:9
相关论文
共 10 条
[1]  
Becker G J, 1991, J Vasc Interv Radiol, V2, P225, DOI 10.1016/S1051-0443(91)72286-0
[2]   THE USE OF ENDOVASCULAR STENTED GRAFTS IN THE MANAGEMENT OF TRAUMATIC FALSE ANEURYSMS - A CAVEAT [J].
CHALMERS, RTA ;
BRITTENDEN, J ;
BRADBURY, AW .
JOURNAL OF VASCULAR SURGERY, 1995, 22 (03) :337-338
[3]  
ELKIN DC, 1955, SURG WORLD WAR 2 VAS
[4]   TRANSLUMINALLY PLACED ENDOVASCULAR STENTED GRAFT REPAIR FOR ARTERIAL TRAUMA [J].
MARIN, ML ;
VEITH, FJ ;
PANETTA, TF ;
CYNAMON, J ;
SANCHEZ, LA ;
SCHWARTZ, ML ;
LYON, RT ;
BAKAL, CW ;
SUGGS, WD .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (03) :466-473
[5]   PERCUTANEOUS TRANSFEMORAL INSERTION OF A STENTED GRAFT TO REPAIR A TRAUMATIC FEMORAL ARTERIOVENOUS-FISTULA [J].
MARIN, ML ;
VEITH, FJ ;
PANETTA, TF ;
CYNAMON, J ;
BARONE, H ;
SCHONHOLZ, C ;
PARODI, JC .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) :299-302
[6]   TRANSLUMINAL PLACEMENT OF A PROSTHETIC GRAFT-STENT DEVICE FOR TREATMENT OF SUBCLAVIAN ARTERY ANEURYSM [J].
MAY, J ;
WHITE, G ;
WAUGH, R ;
YU, WY ;
HARRIS, J .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (06) :1056-1059
[7]  
PARODI JC, 1993, ADV VASCULAR SURGERY, V1, P85
[8]  
PARODI JC, 1993, CURRENT CRITICAL PRO, V4, P264
[9]  
Rich N. M., 1978, VASCULAR TRAUMA
[10]   PERCUTANEOUS AORTIC STENT PLACEMENT FOR LIFE-THREATENING AORTIC RUPTURE DUE TO METASTATIC GERM-CELL TUMOR [J].
TERRY, PJ ;
HOUSER, EE ;
RIVERA, FJ ;
PALMAZ, JC ;
SAROSDY, MF .
JOURNAL OF UROLOGY, 1995, 153 (05) :1631-1634