A performance study of PEMS applied to the Hsinta power station of Taipower

被引:8
作者
Chien, TW
Chu, H [1 ]
Hsu, WC
Tu, YY
Tsai, HS
Chen, KY
机构
[1] Natl Cheng Kung Univ, Dept Environm Engn, Tainan 70101, Taiwan
[2] Taiwan Power Co, Dept Ind Safety & Environm Protect, Taipei, Taiwan
关键词
PEMS; CEMS; RATA; NOx; modeling;
D O I
10.1016/j.atmosenv.2004.09.062
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Predictive emission monitoring systems (PEMS) have been shown to be a promising technology for calculating the emissions from gas-fired stationary sources. One of the first demonstration PEMS in Taiwan was installed and operated successfully at the Hsinta power plant of the Taiwan Power Company (Taipower) in 2000. To improve the accuracy of this PEMS model, further studies were conducted at the same combined cycle gas turbine (CCGT) unit #1 of the Hsinta power plant. To optimize the NOx PEMS model, several functions were progressively developed including a log model, a one-level linear model, a three-level linear model, a 15-variable linear model, and a 15-variable with start-up mode model. The latter gave the relative accuracies (RA) and correlation coefficients between PEMS and a continuous emission monitoring system (CEMS) in the range of 3.38-14.77% and 0.955-0.989, respectively, which fulfill the criteria of the USEPA draft on PEMS performance specifications. Similarly, this model demonstrated RAs for low, medium, high level, and a three-level average less than 20% which meet CEMS requirements set out by Taiwan EPA. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 28 条
  • [1] Predictive emission monitors (PEMS) for NOx generation in process heaters
    Chakravarthy, SSS
    Vohra, AK
    Gill, BS
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2000, 23 (11-12) : 1649 - 1659
  • [2] CHENG AM, 1996, ENV PROGR, V15
  • [3] CHENG AM, 1995, CHEM ENG CHEMP 3 C E
  • [4] CHENG AM, 1995, AICHE SPRING NAT M H
  • [5] A feasibility study on the predictive emission monitoring system applied to the Hsinta power plant of Taiwan power company
    Chien, TW
    Chu, H
    Hsu, WC
    Tseng, TK
    Hsu, CH
    Chen, KY
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2003, 53 (08): : 1022 - 1028
  • [6] COLLINS M, 1994, CHEM ENG
  • [7] Cooper D, 2004, COMMUNICATION
  • [8] Predictive NOx emission monitoring on board a passenger ferry
    Cooper, DA
    Andreasson, K
    [J]. ATMOSPHERIC ENVIRONMENT, 1999, 33 (28) : 4637 - 4650
  • [9] NOx PEMS experience on operating ethylene furnaces
    Croy, RL
    Simpson, CW
    Tipton, DB
    Sinha, P
    Lashier, ME
    [J]. ENVIRONMENTAL PROGRESS, 1997, 16 (04): : 297 - 300
  • [10] GIMENEZ A, 2001, POWER GEN EUR 2001 B