LET, a cold neutron multi-disk chopper spectrometer at ISIS

被引:153
作者
Bewley, R. I. [1 ]
Taylor, J. W. [1 ]
Bennington, S. M. [1 ]
机构
[1] Rutherford Appleton Lab, ISIS Facil, Didcot OX11 0QX, Oxon, England
关键词
Neutron spectroscopy; Instrumentation;
D O I
10.1016/j.nima.2011.01.173
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
LET is a new multi-chopper direct geometry cold neutron spectrometer, recently installed on target station 2 (TS2) at the ISIS spallation neutron source. The characteristics of the primary spectrometer are a 25 m straight super-mirror guide viewing the new highly efficient coupled solid methane moderator system. This combination yields a high incident flux of neutrons with a wide dynamic range of 0.6-80 meV. LET employs a novel flux compression guide design which in combination with two 300 Hz counter rotating choppers produces fine energy resolutions of >= 0.8% delta E/Ei, to be realised with very little flux sacrifice compared to conventional methods. The multi-chopper system is designed to make full use of the long 100 ms time frames of TS2, allowing the user to make multiple measurements within a single frame. The secondary spectrometer is characterised by a wide area position sensitive He-3 multidetector with pi steradians of nearly gapless coverage over the angular range from -40 degrees to +/- 140 degrees in the horizontal plane and +/- 30 degrees in the vertical plane. The multidetector utilises the worlds first 4 m position sensitive He-3 neutron detector tubes. LET has been designed specifically to allow the use of polarised neutrons allowing the user to exploit full XYZ neutron polarisation analysis. In addition a new 9 T magnet has been designed for LET allowing the use of large samples of 25 mm x 25 mm with a 30 degrees vertical opening to make use of the large multidetector. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 24 条
[1]  
ANSELL S, 2006, ADV COLD MODERATORS, V7, P43
[2]  
ANSELL S, 2005, P ICANS 17, V2, P294
[3]   3He polarization for ISIS TS2 phase I instruments [J].
Beecham, C. J. ;
Boag, S. ;
Frost, C. D. ;
McKetterick, T. J. ;
Stewart, J. R. ;
Andersen, K. H. ;
Bentley, P. M. ;
Jullien, D. .
PHYSICA B-CONDENSED MATTER, 2011, 406 (12) :2429-2432
[4]   Design of a low-energy multi-chopper spectrometer for a second target station at ISIS [J].
Bewley, R ;
Eccleston, R .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1) :S218-S220
[5]   Enhancing the flux on a chopper spectrometer with a dual beam compression monochromator [J].
Bewley, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 492 (1-2) :97-104
[6]  
BEWLEY RI, 2009, NOT NEUTRONI LUCE SI, V14, P1
[7]   Neutron spectroscopy for the magnetic anisotropy of molecular clusters [J].
Caciuffo, R ;
Amoretti, G ;
Murani, A ;
Sessoli, R ;
Caneschi, A ;
Gatteschi, D .
PHYSICAL REVIEW LETTERS, 1998, 81 (21) :4744-4747
[8]  
Coldea R., 2001, PHYS REV LETT, V86, P13351338
[9]   An acceptance diagram analysis of the contaminant pulse removal problem with direct geometry neutron chopper spectrometers [J].
Copley, JRD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 510 (03) :318-324
[10]   ON THE USE OF MULTIPLE-SLOT MULTIPLE DISK CHOPPER ASSEMBLIES TO PULSE THERMAL-NEUTRON BEAMS [J].
COPLEY, JRD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (01) :67-76