Use of capacitive and GPR techniques for the non-destructive evaluation of cover concrete

被引:97
作者
Derobert, Xavier
Iaquinta, Jean
Klysz, Gilles
Balayssac, Jean-Paul
机构
[1] LCPC, F-44341 Bouguenais, France
[2] TRL, Wokingham RG40 3GA, Berks, England
[3] INSA Genie Civil, LMDC, F-31077 Toulouse, France
关键词
cover concrete; moisture; ground penetrating radar; capacitive technique;
D O I
10.1016/j.ndteint.2007.06.004
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Two non-destructive techniques, namely ground penetrating radar (GPR) and a more original approach based on capacitive measurement, have been considered in this research project that focuses on the evaluation of cover concrete moisture content. Following a numerical modeling step for the capacitive technique, the two methods were successfully compared during an experimental campaign conducted in the laboratory against several control test slabs. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:44 / 52
页数:9
相关论文
共 29 条
[1]   Design and evaluation of a coaxial transmission line fixture to characterize portland cement concrete [J].
Al-Qadi, IL ;
Riad, SM ;
Mostaf, R ;
Su, W .
CONSTRUCTION AND BUILDING MATERIALS, 1997, 11 (03) :163-173
[2]  
[Anonymous], P 7 INT C GROUND PEN
[3]   Characterization of heterogeneous systems by dielectric spectroscopy [J].
Asami, K .
PROGRESS IN POLYMER SCIENCE, 2002, 27 (08) :1617-1659
[4]  
BARON J, 1977, B PONTS CHAUSSEES, V87, P85
[5]  
BLASZCZYK F, 1993, B PONTS CHAUSSEES, V186, P85
[6]   Sub-surface radar testing of concrete: a review [J].
Bungey, JH .
CONSTRUCTION AND BUILDING MATERIALS, 2004, 18 (01) :1-8
[7]   Imaging of concrete structures [J].
Buyukozturk, O .
NDT & E INTERNATIONAL, 1998, 31 (04) :233-243
[8]  
CLEMENA GG, 1991, CRC HDB NDT CONCRETE
[9]  
Daniels D. J., 2004, GROUND PENETRATING R
[10]  
Diefenderfer BK, 1998, MATER RES SOC SYMP P, V503, P231