Implantable multiprogrammable microstimulator dedicated to bladder control

被引:11
作者
Arabi, K
Sawan, M
机构
[1] Dept. of Elec. and Comp. Engineering, Ecl. Polytech. de Montréal, Station Centre-ville, Montreal, Que. H3C 3A7
[2] Tehran Polytechnic, Tehran
[3] École Polytechnique, Montreal, Que.
关键词
implant; multichannel microstimulator; urinary dysfunctions;
D O I
10.1007/BF02637016
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An implantable multiprogrammable microstimulator that is intended to restore normal bladder functions (retention and incontinence) to spinal cord injured patients is presented. The implantable microstimulator circuitry is externally controlled and is powered by a single encoded radio frequency carrier and has four bipolar (eight monopolar) independently controlled channels. It offers a higher degree of reprogrammability and flexibility and can be used in any neuromuscular applications. The implant system is adaptable to the patient's needs and to future developments in stimulation algorithms, without changing the implant. Features of the microstimulator include its capabilities to generate a wide range of waveforms and to combine up to four different programmable frequencies in each wave train. By using a forward error detection and correction communication protocol, the reliability of the implant is increased. The chip has been designed for structural testability by means of a scan-based test approach and uses circuit techniques to reduce power consumption and ensure long-term stability.
引用
收藏
页码:9 / 12
页数:4
相关论文
共 10 条
[1]  
ARABI K, 1994, P IEEE EMBS 16 ANN C
[2]   IMPLANT TO EMPTY BLADDER OR CLOSE URETHRA [J].
BRINDLEY, GS .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1977, 40 (04) :358-369
[3]  
BROCKLEHURST JC, 1982, MED INSTRUM, V16, P167
[4]   ELECTRICAL-STIMULATION INDUCED SPHINCTER FATIGUE DURING VOIDING [J].
LI, JS ;
HASSOUNA, M ;
SAWAN, M ;
DUVAL, F ;
ELHILALI, MM .
JOURNAL OF UROLOGY, 1992, 148 (03) :949-952
[5]   VERSATILE THREE-CHANNEL STIMULATION CONTROLLER FOR RESTORATION OF BLADDER FUNCTION IN PARAPLEGIA [J].
PERKINS, TA .
JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (03) :268-271
[6]   COMPUTERIZED TRANSCUTANEOUS CONTROL OF A MULTICHANNEL IMPLANTABLE URINARY PROSTHESIS [J].
SAWAN, M ;
DUVAL, F ;
HASSOUNA, MM ;
LI, JS ;
ELHILALI, MM ;
LACHANCE, J ;
LECLAIR, M ;
POURMEHDI, S ;
MOUINE, J .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :600-609
[7]  
Sawan Mohammad, 1993, Biomedical Instrumentation and Technology, V27, P143
[8]   ELECTRICAL-STIMULATION IN THE CLINICAL MANAGEMENT OF THE NEUROGENIC BLADDER [J].
TANAGHO, EA ;
SCHMIDT, RA .
JOURNAL OF UROLOGY, 1988, 140 (06) :1331-1339
[9]   INHIBITING THE HYPERREFLEXIC BLADDER WITH ELECTRICAL-STIMULATION IN A SPINAL ANIMAL-MODEL [J].
WALTER, JS ;
WHEELER, JS ;
ROBINSON, CJ ;
WURSTER, RD .
NEUROUROLOGY AND URODYNAMICS, 1993, 12 (03) :241-253
[10]  
WEI M, 1994, 26 SE S SYST THEOR A