Electrochemical measurement of endogenously produced nitric oxide in brain slices using Nafion/o-phenylenediamine modified carbon fiber microelectrodes

被引:46
作者
Ferreira, NR
Ledo, A
Frade, JG
Gerhardt, GA
Laranjinha, J
Barbosa, RM [1 ]
机构
[1] Univ Coimbra, Ctr Neurosci & Cell Biol, Coimbra, Portugal
[2] Univ Kentucky, Dept Anat & Neurobiol, Lexington, KY 40356 USA
[3] Univ Coimbra, Fac Pharm, Biochem Lab, Coimbra, Portugal
[4] Univ Coimbra, Fac Pharm, Instrumental Anal Lab, P-3000295 Coimbra, Portugal
关键词
nitric oxide; microelectrode; hippocampus; Nafion; o-phenylenediamine;
D O I
10.1016/j.aca.2004.12.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The role of nitric oxide ((NO)-N-.) as a regulatory diffusible molecule in the brain requires the evaluation of its concentration dynamics. In this work, we have developed microelectrodes suitable for real time electrochemical measurements of (NO)-N-. in vitro. Nation and o-phenylenediamine were used to modify the surface of carbon fiber microelectrodes (8 mu m diameter; approximate to 100 mu m tip length). Coating with Nafion was done at 170 degrees C and the o-phenylenediamine solution was electropolimerized on the carbon surface. (NO)-N-. peak potential (+0.78 +/- 0.03 V versus Ag/AgCl) was determined by square wave voltammetry with (NO)-N-. solutions prepared from the-generating compound diethylenetriamine/nitric oxide (DETA/NO). Microelectrodes were calibrated by amperometry at a potential of +0.90 V versus Ag/AgCl. They showed good sensitivity (954 +/- 217 pA/mu M; n = 6) and linearity to (NO)-N-. in the concentration range of 100-1000 nM. They were also characterized in terms of detection limit (6 2 nM, n = 4), response time at 50% (1 s), and selectivity against interferents, such as nitrite (780 84: 1, n = 6), ascorbic acid (750 187: 1, n = 6) or dopamine (18 2: 1, n = 6). Injections of 1 mM L-glutamate, 1 mM L-arginine, and 0.1 mM N-methyl-D-aspartate did not produce changes in background current. Finally, the microelectrodes were used to measure (NO)-N-. concentration dynamics in rat hippocampal brain slices stimulated with L-glutamate and N-methyl-D-aspartate. Taken together, the data indicate that the microelectrodes exhibit the proper sensitivity and selectivity for studies of (NO)-N-. dynamics in brain slices (in vitro) and possibly in whole brain (in vivo) recordings. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 42 条
[1]   MEASUREMENT OF NITRIC-OXIDE IN BIOLOGICAL MODELS [J].
ARCHER, S .
FASEB JOURNAL, 1993, 7 (02) :349-360
[2]   Control of pulsatile 5-MT/insulin secretion from single mouse pancreatic islets by intracellular calcium dynamics [J].
Barbosa, RM ;
Silva, AM ;
Tomé, AR ;
Stamford, JA ;
Santos, RM ;
Rosário, LM .
JOURNAL OF PHYSIOLOGY-LONDON, 1998, 510 (01) :135-143
[3]  
BECKMAN JS, 1994, METHOD ENZYMOL, V233, P229
[4]   Electrochemical nitric oxide sensors for biological samples - Principle, selected examples and applications [J].
Bedioui, F ;
Villeneuve, N .
ELECTROANALYSIS, 2003, 15 (01) :5-18
[5]  
BRAZELL MP, 1987, J NEUROSCI METH, V22, P172
[6]   Electrochemical sensing of nitric oxide for biological systems: methodological approach and new insights in examining interfering compounds [J].
Brunet, A ;
Pailleret, A ;
Devynck, MA ;
Devynck, J ;
Bedioui, F .
TALANTA, 2003, 61 (01) :53-59
[7]   Electrochemical detection of nitric oxide using polymer modified electrodes [J].
Ciszewski, A ;
Milczarek, G .
TALANTA, 2003, 61 (01) :11-26
[8]   Can voltammetry measure nitrogen monoxide (NO) and/or nitrites? [J].
Crespi, F ;
Campagnola, M ;
Neudeck, A ;
McMillan, K ;
Rossetti, Z ;
Pastorino, A ;
Garbin, U ;
Fratta-Pasini, A ;
Reggiani, A ;
Gaviraghi, G ;
Cominacini, L .
JOURNAL OF NEUROSCIENCE METHODS, 2001, 109 (01) :59-70
[9]  
Dawson VL, 1998, PROG BRAIN RES, V118, P215
[10]   Electropolymerized manganese porphyrin/polypyrrole films as catalytic surfaces for the oxidation of nitric oxide [J].
Diab, N ;
Schuhmann, W .
ELECTROCHIMICA ACTA, 2001, 47 (1-2) :265-273