An adiabatic multiple spin-echo pulse sequence: Removal of systematic errors due to pulse imperfections and off-resonance effects

被引:38
作者
Zweckstetter, M [1 ]
Holak, TA [1 ]
机构
[1] Max Planck Inst Biochem, D-82152 Martinsried, Germany
关键词
spin-echo; adiabatic fast passage pulses; AFP-CPMG; AFP-MLEV-4; T-2 relaxation time;
D O I
10.1006/jmre.1998.1437
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Application of AFP (adiabatic fast passage) pulses for removal of systematic errors associated with multiple spin-echo sequences is demonstrated. The adiabatic fast passage pulses facilitate minimization of cumulative pulse errors for all three components of magnetization. It is also shown that off-resonance effects present in conventional CPMG sequences which degrade image quality in magnetic resonance imaging and introduce systematic errors in measured T-2 relaxation time peak amplitudes can be suppressed by introduction of AFP pulses without any degradation of overall signal intensity. The technique has been tested on the N-15 spin-spin relaxation time measurements of a 110 amino acid domain of the F-actin cross-linking protein. (C) 1998 Academic Press.
引用
收藏
页码:134 / 147
页数:14
相关论文
共 47 条
[1]   BROAD-BAND AND ADIABATIC INVERSION OF A 2-LEVEL SYSTEM BY PHASE-MODULATED PULSES [J].
BAUM, J ;
TYCKO, R ;
PINES, A .
PHYSICAL REVIEW A, 1985, 32 (06) :3435-3447
[2]   BROAD-BAND POPULATION-INVERSION BY PHASE MODULATED PULSES [J].
BAUM, J ;
TYCKO, R ;
PINES, A .
JOURNAL OF CHEMICAL PHYSICS, 1983, 79 (09) :4643-4644
[3]  
BENDALL MR, 1987, MAGNET RESON MED, V4, P493
[4]  
BLOCH F, 1946, PHYS REV, V70, P460, DOI 10.1103/PhysRev.70.460
[5]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[6]   EFFICIENCY IN MULTIDIMENSIONAL NMR BY OPTIMIZED RECORDING OF TIME POINT PHASE PAIRS IN EVOLUTION PERIODS AND THEIR SELECTIVE LINEAR TRANSFORMATION [J].
CIESLAR, C ;
ROSS, A ;
ZINK, T ;
HOLAK, TA .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1993, 101 (01) :97-101
[7]   A SELECTIVE ADIABATIC SPIN-ECHO PULSE [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A .
JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (02) :324-334
[8]   A REDUCED POWER SELECTIVE ADIABATIC SPIN-ECHO PULSE SEQUENCE [J].
CONOLLY, S ;
GLOVER, G ;
NISHIMURA, D ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) :28-38
[9]   ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) :34-47
[10]   Removal of systematic errors associated with off-resonance oscillations in T-2 measurements [J].
Czisch, M ;
King, GC ;
Ross, A .
JOURNAL OF MAGNETIC RESONANCE, 1997, 126 (01) :154-157