Evaluation of the harmony soundprocessor in combination with the speech coding strategy HiRes 120

被引:39
作者
Brendel, Martina [1 ]
Buechner, Andreas [1 ]
Krueger, Beate [1 ]
Frohne-Buechner, Carolin [1 ,2 ]
Lenarz, Thomas [1 ]
机构
[1] Hannover Med Sch, Dept Otolaryngol, Hannover, Germany
[2] Adv Bion GmbH, Hannover, Germany
关键词
harmony soundprocessor; HiRes; 120; speech coding strategy;
D O I
10.1097/mao.0b013e31816335c6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: The Advanced Bionics Harmony BTE processor was developed to support the new speech coding strategy HiRes 120 with a resolution of 120 channels based on "current steering." Compared with the previous Auria, the front end has been redesigned and power consumption reduced. Study Design: HiRes 120 as well as the impact of the improved Harmony processing concerning a better speech understanding were evaluated. Subject's performance was evaluated using a test battery of the Hochmair-Schulz-Moser (HSM) sentence test and questionnaires regarding general sound quality, music perception, battery-life time, and processor handling. Patients: In the first study group, 11 postlingually deafened adult subjects participated with a minimum of 9 months experience. The second study group consisted of 14 postlingually deafened adult subjects with a minimum of 2 years experience. Interventions: Tested were the 2 speech coding strategies HiRes and HiRes 120 on the Harmony and the clinical system, respectively. Main Outcome Measures: Speech perception tests in quiet, in CCITT noise, as well as with a competing talker, questionnaires regarding sound quality and handling and perceptual channel tests. Results: A total of 84% showed a clear preference for the Harmony processor compared with their previous processor with HiRes. The speech test results showed a 7.7% average increase in the HSM sentence test with 5 dB SNR competing talker. Conclusion: The majority of the subjects wanted to change to the new Harmony processor because of a better understanding in everyday life, handling, and improved battery-life time.
引用
收藏
页码:199 / 202
页数:4
相关论文
共 7 条
[1]  
BATTMER RD, 2002, CLARIION CII HIGH RE
[2]  
DOWNING M, 2005, ARO ABSTRACTS, V28, P85
[3]  
GAULT A, 9 INT C COCHL IMPL R
[4]  
HochmairDesoyer I, 1997, AM J OTOL, V18, pS83
[5]   Using current steering to increase spectral resolution in CII and HiRes 90K users [J].
Koch, Dawn Burton ;
Downing, Mark ;
Osberger, Mary Joe ;
Litvak, Leonid .
EAR AND HEARING, 2007, 28 (02) :38S-41S
[6]   Understanding speech in modulated interference: Cochlear implant users and normal-hearing listeners [J].
Nelson, PB ;
Jin, SH ;
Carney, AE ;
Nelson, DA .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (02) :961-968
[7]   PITCH PERCEPTION BY COCHLEAR IMPLANT SUBJECTS [J].
TOWNSHEND, B ;
COTTER, N ;
VANCOMPERNOLLE, D ;
WHITE, RL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1987, 82 (01) :106-115