Determination of endocrine-disrupting compounds in water samples by on-line solid-phase extraction-programmed-temperature vaporisation-gas chromatography-mass spectrometry

被引:50
作者
Brossa, L [1 ]
Marcé, RM [1 ]
Borrull, F [1 ]
Pocurull, E [1 ]
机构
[1] Univ Rovira & Virgili, Dept Quim Analit & Quim Organ, Tarragona 43005, Spain
关键词
water analysis; sample preparation; injection methods; programmed-temperature vaporiser; automation; environmental analysis; endocrine disruptors; pesticides; phthalates;
D O I
10.1016/S0021-9673(03)00649-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed an automated on-line solid-phase extraction (SPE)-gas chromatography-mass spectrometry method to determine a group of endocrine disruptors in water samples. The interface device used for connecting SPE with GC was a programmed-temperature vaporiser (PTV) whose liner was packed with Tenax. We optimized the parameters that affected both SPE and PTV working in solvent vent mode. The performance of the method was tested with several environmental water samples. The limits of detection of the method were between 0.001 and 0.036 mug l(-1) under full-scan acquisition mode. We determined phthalates and adipate in all real samples at concentrations between 0.11 and 8.10 mug l(-1). Atrazine and p,p'-DDE were also found in an irrigation stream water sample at 0.16 and 0.04 mug l(-1), respectively. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:41 / 50
页数:10
相关论文
共 24 条
[1]   Application of on-line solid-phase extraction-gas chromatography-mass spectrometry to the determination of endocrine disruptors in water samples [J].
Brossa, L ;
Marcé, RM ;
Borrull, F ;
Pocurull, E .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :287-294
[2]   Endocrine disruptors: Present issues, future directions [J].
Crews, D ;
Willingham, E ;
Skipper, JK .
QUARTERLY REVIEW OF BIOLOGY, 2000, 75 (03) :243-260
[3]  
Croley TR, 2000, RAPID COMMUN MASS SP, V14, P1087
[4]   Review of analytical methods for the determination of estrogens and progestogens in waste waters [J].
De López Aida M.J. ;
Barceló D. .
Fresenius' Journal of Analytical Chemistry, 2001, 371 (4) :437-447
[5]   Determination of steroid sex hormones and related synthetic compounds considered as endocrine disrupters in water by fully automated on-line solid-phase extraction-liquid chromatography-diode array detection [J].
de Alda, MJL ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2001, 911 (02) :203-210
[6]   Programmed temperature vaporisers-based large volume injection in capillary gas chromatography [J].
Engewald, W ;
Teske, J ;
Efer, J .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :143-161
[7]   The endocrine disruptor screening program developed by the US Environmental Protection Agency [J].
Fenner-Crisp, PA ;
Maciorowski, AF ;
Timm, GE .
ECOTOXICOLOGY, 2000, 9 (1-2) :85-91
[8]   Development of the ELISAs for detection of hormone-disrupting chemicals [J].
Goda, Y ;
Kobayashi, A ;
Fukuda, K ;
Fujimoto, S ;
Ike, M ;
Fujita, M .
WATER SCIENCE AND TECHNOLOGY, 2000, 42 (7-8) :81-88
[9]  
Hemmer MJ, 2001, ENVIRON TOXICOL CHEM, V20, P336, DOI [10.1897/1551-5028(2001)020&lt
[10]  
0336:EOPNMA&gt