摘要
Study objectives: The peak inspiratory Bow rates (PIFRs) generated by cystic fibrosis (CF) and COPD patients through a range of clinically relevant resistances have not yet been reported (to our knowledge). The objectives of this study were to (1) explore a relevant range of resistive loads and address whether patients with stable CF and COPD can generate the PIFR sufficient to disperse dry-powder inhalants (DPI) and (2) determine whether the optimal inspiratory Bow rate effective for delivery of aerosolized pharmacologic therapeutic agents can be attained with a comfort rating acceptable to subjects. Design: Prospective, controlled, subject-blinded study. Setting: Pulmonary function laboratory at the VA Pale Alto Health Care System, Patients or participants: Thirty-six subjects, including 12 healthy volunteers, 12 subjects with CF, and 12 subjects with COPD were studied, Measurements: Studies of dynamic lung function and PIFR without and with varying resistances were obtained at a single laboratory visit. Results: Dynamic lung function and PIFR varied inversely with the resistive load for all patient groups and did not correlate with the disease severity, as indicated by FEV1 of percent predicted, The average subjective comfort rating for any given resistive load was similar for subjects with CF and COPD, Conclusions: These results support the conclusion that subjects with stable CF and COPD of varying severity can comfortably generate the necessary flow rates to operate new and currently available DPIs over a wide range of inspiratory resistance.
引用
收藏
页码:988 / 992
页数:5
相关论文
共 32 条
[1]  
*AM THOR SOC, AM REV RESPO DIS, V136, P1285
[2]  
ANDERSON P, 1993, EUR RESP J S, V17
[3]  
BECKLAKE M, 1991, AM REV RESPIR DIS, V144, P1202
[4]  
BLACK LF, 1969, AM REV RESPIR DIS, V99, P696
[5]   Effect of different inspiratory maneuvers on FEV(1) in patients with cystic fibrosis [J].
Braggion, C ;
Pradal, U ;
Mastella, G ;
Coates, AL ;
MilicEmili, J .
CHEST, 1996, 110 (03) :642-647
[6]  
CLARK A, 1994, RESP DRUG DELIVERY, V4, P117
[7]   THE RELATIONSHIP BETWEEN POWDER INHALER RESISTANCE AND PEAK INSPIRATORY CONDITIONS IN HEALTHY-VOLUNTEERS - IMPLICATIONS FOR IN-VITRO TESTING [J].
CLARK, AR ;
HOLLINGWORTH, AM .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1993, 6 (02) :99-110
[8]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[9]  
HANSEN N, 1993, EUR RESPIR J, V17, pA196
[10]   DRY POWDER INHALERS ARE BIOEQUIVALENT TO METERED-DOSE INHALERS - A STUDY USING A NEW URINARY ALBUTEROL (SALBUTAMOL) ASSAY TECHNIQUE [J].
HINDLE, M ;
NEWTON, DAG ;
CHRYSTYN, H .
CHEST, 1995, 107 (03) :629-633