Precautions in the use of intensity-modulated radiation therapy

被引:14
作者
Welsh, JS
Limmer, JP
Howard, SP
Diamond, D
Harari, PM
Tomé, W
机构
[1] Univ Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[3] UW Canc Ctr, Wausau Hosp, Wausau, WI 54401 USA
[4] Florida Hosp, Inst Canc, Dept Radiat Oncol, Altamonte Springs, FL 32701 USA
关键词
IMRT; radiation dose-rate; bystander effect; low-dose hypersensitivity;
D O I
10.1177/153303460500400209
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity-modulated radiation therapy (IMRT) represents a significant technological advancement in the ability to deliver highly conformal radiation therapy. Thanks to increased availability, general clinical implementation has become progressively more common. However, there are several precautions worthy of comment regarding the clinical applications of IMRT. In theory, the increased irradiated volume and leakage radiation that occasionally accompanies IMRT could contribute to unanticipated complications and safety concerns. The protracted delivery time of IMRT with the associated increased linac monitor units can result in photoactivation of elements within the linac collimator, thereby inadvertently increasing radiation exposure to patients and staff when high-energy photons are used. The increased volumes of normal tissue exposed to lower doses of radiation through IMRT theoretically could promote carcinogenesis and complications due to the bystander effect, low-dose hyper-radiosensitivity, and diminished repair of double strand DNA breaks at very low doses. Tumor control may be adversely affected by the lower radiation dose-rates of delivery sometimes associated with IMRT as well the occasionally seen low dose "cold shoulder" on the dose-volume histograms. Unusual clinical reactions can appear as a result of the complex, unfamiliar dose-distributions occasionally generated by IMRT treatment planning. Here we discuss some of the precautions worthy of consideration when using IMRT and how these might be addressed in routine practice.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 38 条
  • [1] The biological effectiveness of intermittent irradiation as a function of overall treatment time: Development of correction factors for linac-based stereotactic radiotherapy
    Benedict, SH
    Lin, PS
    Zwicker, RD
    Huang, DT
    SchmidtUllrich, RKA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (04): : 765 - 769
  • [2] Followill David S, 2003, J Appl Clin Med Phys, V4, P189, DOI 10.1120/1.1571671
  • [3] Loss of biological effect in prolonged fraction delivery
    Fowler, JF
    Welsh, JS
    Howard, SP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01): : 242 - 249
  • [4] Intensity-modulated radiation therapy: The inverse, the converse, and the perverse
    Glatstein, E
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) : 272 - 281
  • [5] Goffman TE, 2002, RADIAT RES, V158, P115, DOI 10.1667/0033-7587(2002)158[0115:IMRT]2.0.CO
  • [6] 2
  • [7] Radiation-induced second cancers: The impact of 3D-CRT and IMRT
    Hall, EJ
    Wuu, CS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 83 - 88
  • [8] Huo LH, 2001, RADIAT RES, V156, P521, DOI 10.1667/0033-7587(2001)156[0521:HMIIBC]2.0.CO
  • [9] 2
  • [10] Low-dose hypersensitivity: Current status and possible mechanisms
    Joiner, MC
    Marples, B
    Lambin, P
    Short, SC
    Turesson, I
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (02): : 379 - 389