Use of harmonic imaging without echocardiographic contrast to improve two-dimensional image quality

被引:128
作者
Spencer, KT
Bednarz, J
Rafter, PG
Korcarz, C
Lang, RM
机构
[1] Univ Chicago Hosp, Cardiol Sect, Noninvas Cardiac Imaging Lab, Chicago, IL 60637 USA
[2] Hewlett Packard Co, Andover, MA USA
关键词
D O I
10.1016/S0002-9149(98)00457-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to determine whether harmonic imaging (HI) Improves endocardial visualization during 2-dimensional echocardiography without echocardiographic contrast, HI differs from fundamental imaging (FI) by transmitting ultrasound at one frequency and receiving at twice the transmitted frequency. This technique has been used in conjunction with contrast echocardiography to enhance myocardial contrast visualization, HI and FI were sequentially performed in 20 patients. Images were digitally stored and subsequently reviewed by 2 observers for the quality of endocardial visualization. in addition, acoustic quantification was performed in both FI and Hi modes and endocardial tracking qualitatively judged, HI was compared with FI during dobutamine stress echocardiography in 17 patients who were imaged at baseline and peak stress. Overall, the harmonic images had less clutter and better myocardial blood contrast, Individual segments were better visualized with HI in 30% to 73% of cases. The acoustic quantification endocardial tracking was rated better with HI in 67% of short-axis views and in 58% of apical 4-chamber views. During dobutamine stress testing the overall number of interpretable segments improved from 64% for FI to 84% with HI. Many segments traditionally difficult to image were improved with HI. HI without the use of contrast agents improved endocardial visualization during routine 2-dimensional echocardiography, This improved endocardial visualization led to better endocardial tracking with acoustic quantification and to more segments being clinically interpretable during dobutamine stress testing. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:794 / 799
页数:6
相关论文
共 20 条
[1]  
Bednarz J E, 1995, J Am Soc Echocardiogr, V8, P293, DOI 10.1016/S0894-7317(05)80040-9
[2]   EARLY RECOVERY OF REGIONAL LEFT-VENTRICULAR FUNCTION AFTER REPERFUSION IN ACUTE MYOCARDIAL-INFARCTION ASSESSED BY SERIAL TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
BOURDILLON, PDV ;
BRODERICK, TM ;
WILLIAMS, ES ;
DAVIS, C ;
DILLON, JC ;
ARMSTRONG, WF ;
FINEBERG, N ;
RYAN, T ;
FEIGENBAUM, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (11) :641-646
[3]  
Broderick T M, 1989, J Am Soc Echocardiogr, V2, P315
[4]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[5]   Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging [J].
Christopher, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (01) :125-139
[6]   OPACIFICATION AND BORDER DELINEATION IMPROVEMENT IN PATIENTS WITH SUBOPTIMAL ENDOCARDIAL BORDER DEFINITION IN ROUTINE ECHOCARDIOGRAPHY - RESULTS OF THE PHASE-III ALBUNEX MULTICENTER TRIAL [J].
CROUSE, LJ ;
CHEIRIF, J ;
HANLY, DE ;
KISSLO, JA ;
LABOVITZ, AJ ;
RAICHLEN, JS ;
SCHUTZ, RW ;
SHAH, PM ;
SMITH, MD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1494-1500
[7]  
CROUSE LJ, 1992, AM J CARDIOL, V69, P42
[8]  
Dunn F., 1981, IEEE ULTR S, P527
[9]   Myocardial contrast echocardiography in acute myocardial infarction using aortic root injections of microbubbles in conjunction with harmonic imaging: Potential application in the cardiac catheterization laboratory [J].
Firschke, C ;
Lindner, JR ;
Goodman, NC ;
Skyba, DM ;
Wei, K ;
Kaul, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (01) :207-216
[10]   Second harmonic imaging of an intravenously administered echocardiographic contrast agent - Visualization of coronary arteries and measurement of coronary blood flow [J].
Mulvagh, SL ;
Foley, DA ;
Aeschbacher, BC ;
Klarich, KK ;
Seward, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) :1519-1525