Angiographic film subtraction using a laser digitizer and computer processing

被引:2
作者
Boone, JM [1 ]
Corrigan, NM [1 ]
Hecht, ST [1 ]
Link, DP [1 ]
机构
[1] Univ Calif Davis, Med Ctr, Dept Radiol, Sacramento, CA 95817 USA
关键词
angiography; film subtraction; warping algorithm; digital image processing; image registration;
D O I
10.1007/BF03178078
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Digital subtraction angiography has been accepted as an invaluable clinical tool over the past decade; however, film-screen-based angiography is still performed routinely when high-resolution or large field-of-view angiograms are needed. A technique is presented whereby two films from an angiographic sequence are digitized using a high-resolution laser digitizer, anal the digitized images are aligned, subtracted, and displayed using the computer. To accommodate for some types of patient motion, an image warping algorithm is presented and discussed in detail. The warping algorithm is piecewise linear, using triangular regions for warping, resulting in a global nonlinear transform across triangle elements. An algorithm describing optimal triangle selection also is discussed. The results show that subtraction images of excellent quality can be produced by the proposed technique, and suggest that, in some settings, digitized subtraction films may be preferred over conventional film subtraction. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:159 / 167
页数:9
相关论文
共 9 条
[1]
ANALYSIS AND CORRECTION OF IMPERFECTIONS IN THE IMAGE INTENSIFIER-TV-DIGITIZER IMAGING CHAIN [J].
BOONE, JM ;
SEIBERT, JA ;
BARRETT, WA ;
BLOOD, EA .
MEDICAL PHYSICS, 1991, 18 (02) :236-242
[2]
FLUID EQUATIONS APPLIED TO BLOOD-FLOW MEASUREMENT USING DIGITAL VIDEODENSITOMETRY [J].
CLOSE, RA ;
DUCKWILER, GR ;
VINUELA, F .
INVESTIGATIVE RADIOLOGY, 1992, 27 (07) :504-509
[3]
Gillespy T 3rd, 1994, J Digit Imaging, V7, P51
[4]
Use of personal computers and digitized film angiograms to produce subtraction angiograms [J].
Kofler, JM ;
Gray, JE ;
Cesar, LJ .
RADIOGRAPHICS, 1996, 16 (02) :401-407
[5]
SEGMENTATION, MODELING AND RECONSTRUCTION OF ARTERIAL BIFURCATIONS IN DIGITAL ANGIOGRAPHY [J].
PELLOT, C ;
HERMENT, A ;
SIGELLE, M ;
HORAIN, P ;
PERONNEAU, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (06) :576-583
[6]
CORRECTION OF SPATIAL DISTORTION IN MAGNETIC-RESONANCE ANGIOGRAPHY FOR RADIOSURGICAL TREATMENT PLANNING OF CEREBRAL ARTERIOVENOUS-MALFORMATIONS [J].
SCHAD, LR ;
EHRICKE, HH ;
WOWRA, B ;
LAYER, G ;
ENGENHART, R ;
KAUCZOR, HU ;
ZABEL, HJ ;
BRIX, G ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :609-621
[7]
Image-processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus [J].
Spencer, T ;
Olson, JA ;
McHardy, KC ;
Sharp, PF ;
Forrester, JV .
COMPUTERS AND BIOMEDICAL RESEARCH, 1996, 29 (04) :284-302
[8]
OPTIMAL SAMPLING INTERVAL AND EDGE-DETECTION ALGORITHM FOR MEASUREMENT OF BLOOD-VESSEL DIAMETER ON A CINEANGIOGRAM [J].
UYAMA, C ;
KITA, Y ;
MATSUSITA, S .
INVESTIGATIVE RADIOLOGY, 1993, 28 (12) :1128-1133
[9]
AUTOMATED AND ACCURATE ASSESSMENT OF THE DISTRIBUTION, MAGNITUDE, AND DIRECTION OF PINCUSHION DISTORTION IN ANGIOGRAPHIC IMAGES [J].
VANDERZWET, PMJ ;
MEYER, DJH ;
REIBER, JHC .
INVESTIGATIVE RADIOLOGY, 1995, 30 (04) :204-213